Interlaminar Insulation Faults Detection and Quality Assessment of Magnetic Cores Using Flux Injection Probe
- 16 March 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 30 (5) , 2205-2214
Abstract
Interlaminar faults between laminations of the magnetic cores increase core losses and could cause major damage to electrical machines. A system has been developed to detect an interlaminar fault between the laminations of the magnetic cores by means of the flux injection probe (FIP). Experimental work was carried out to calibrate the measuring system and qualify its accuracy over a wide measurement range. Application of a prototype FIP to quality assessment of transformer laminations was investigated in two stages: 1) inspection of stack of laminations with known interlaminar faults applied by artificial shorts and 2) inspection of stack of laminations with unknown quality. The experimental results show that the developed system is capable of detecting an interlaminar fault between as few as two laminations.Keywords
This publication has 9 references indexed in Scilit:
- Eddy Current Loss Estimation of Edge Burr-Affected Magnetic Laminations Based on Equivalent Electrical Network—Part II: Analytical Modeling and Experimental ResultsIEEE Transactions on Power Delivery, 2013
- Eddy Current Loss Estimation of Edge Burr-Affected Magnetic Laminations Based on Equivalent Electrical Network—Part I: Fundamental Concepts and FEM ModelingIEEE Transactions on Power Delivery, 2013
- A Device for the Study of Electrical Steel Losses in Stator Lamination StacksIEEE Transactions on Industrial Electronics, 2013
- A Stator Core Quality Assessment Technique for Inverter-Fed Induction Machines2008
- Experimental Study of Inter-Laminar Core Fault Detection Techniques Based onLow Flux Core ExcitationIEEE Transactions on Energy Conversion, 2006
- An Advanced Technique for Detecting Inter-Laminar Stator Core Faults in Large Electric MachinesIEEE Transactions on Industry Applications, 2005
- An Iron Core Probe Based Inter-Laminar Core Fault Detection Technique for Generator Stator CoresIEEE Transactions on Energy Conversion, 2005
- A New Method for Synchronous Generator Core Quality EvaluationIEEE Transactions on Energy Conversion, 2004
- Inspection of stator cores in large machines with a low yoke induction method-measurement and analysis of interlamination short-circuitsIEEE Transactions on Energy Conversion, 2001