Intraoperative Use of the Vacuum Bell for Elevating the Sternum During the Nuss Procedure
- 1 November 2012
- journal article
- research article
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 22 (9) , 934-936
Abstract
Objective: To evaluate the routine use of the vacuum bell for elevating the sternum during minimally invasive repair of pectus excavatum (MIRPE) (the Nuss procedure). Subjects and Methods: This was a retrospective evaluation of a prospective database including all patients who underwent MIRPE at our institution between 2005 and 2010. Data included the patient's demographic characteristics, age at surgery, gender, Haller index, duration of surgery, and intraoperative complications. Results: Fifty patients from 9 to 28 years old (average, 14.95 years) were observed, including 39 males and 11 females. The preoperative Haller index was between 3.25 and 7.4 (average, 5.05). Mean duration of surgery was 58 minutes (range, 45–92 minutes). The use of the vacuum bell led to a clear elevation of the sternum as confirmed by thoracoscopy. Advancement of the pectus introducer and placement of the pectus bar were safe, successful, and uneventful in all patients. No cardial and/or pericardial lesion was noted as well as no lesion of the mammary vessels. Conclusions: The intraoperative use of the vacuum bell during the MIRPE is safe and effective as it facilitates the retrosternal dissection and the insertion of the pectus bar. If available, we recommend the routine use of this device for MIRPE.Keywords
This publication has 17 references indexed in Scilit:
- Twenty-One Years of Experience With Minimally Invasive Repair of Pectus Excavatum by the Nuss Procedure in 1215 PatientsAnnals of Surgery, 2010
- Near-fatal bleeding after transmyocardial ventricle lesion during removal of the pectus bar after the Nuss procedureThe Journal of Thoracic and Cardiovascular Surgery, 2009
- Infectious complications after the Nuss repair in a series of 863 patientsJournal of Pediatric Surgery, 2007
- The vacuum bell for treatment of pectus excavatum: an alternative to surgical correction?European Journal of Cardio-Thoracic Surgery, 2006
- A Life-Threatening Complication of the Nuss-Procedure for Pectus ExcavatumThe Annals of Thoracic Surgery, 2006
- Delayed near-fatal hemorrhage after Nuss bar displacementJournal of Pediatric Surgery, 2005
- Should an infected Nuss bar be removed?Journal of Pediatric Surgery, 2005
- The vacuum chest wall lifter: an innovative, nonsurgical addition to the management of pectus excavatumJournal of Pediatric Surgery, 2005
- Haemopericardium causing cardiac tamponade: a late complication of pectus excavatum repairHeart, 2004
- Minimally Invasive Repair of Pectus Excavatum - The Nuss Procedure. A European Multicentre ExperienceEuropean Journal of Pediatric Surgery, 2002