Abstract
To perform a dosimetric evaluation of four different simultaneous integrated boost whole brain radiotherapy modalities with hippocampus and inner ear avoidance in the treatment of limited brain metastases. Computed tomography/magnetic resonance imaging data of 10 patients with limited (1–5) brain metastases were used to replan step-and-shoot intensity-modulated radiotherapy (sIMRT), dynamic intensity-modulated radiation therapy (dIMRT), volumetric-modulated arc therapy (VMAT), and helical tomotherapy (Tomo). The prescribed doses of 40–50 Gy in 10 fractions and 30 Gy in 10 fractions were simultaneously delivered to the metastatic lesions and the whole-brain volume, respectively. The hippocampal dose met the RTOG 0933 criteria for hippocampal avoidance (Dmax ≤17 Gy, D100% ≤10 Gy). The inner ear dose was restrained to Dmean ≤15 Gy. Target coverage (TC), homogeneity index (HI), conformity index (CI), maximum dose (Dmax), minimum dose (Dmin) and dose to organs at risk (OARs) were compared. All plans met the indicated dose restrictions. The mean percentage of planning target volume of metastases (PTVmets) coverage ranged from 97.1 to 99.4%. For planning target volume of brain (PTVbrain), Tomo provided the lowest average D2% (37.5 ± 2.8 Gy), the highest average D98% (25.2 ± 2.0 Gy), and the best TC (92.6% ± 2.1%) and CI (0.79 ± 0.06). The two fixed gantry IMRT modalities (step and shot, dynamic) provided similar PTVbrain dose homogeneity (both 0.76). Significant differences across the four approaches were observed for the maximum and minimum doses to the hippocampus and the maximum doses to the eyes, lens and optic nerves. All four radiotherapy modalities produced acceptable treatment plans with good avoidance of the hippocampus and inner ear. Tomo obtained satisfactory PTVbrain coverage and the best homogeneity index. Clinicaltrials.gov, NCT03414944 . Registered 29 January 2018
Funding Information
  • the Shandong Key Research and Development Plan (2017CXGC1209, 2017GSF18164)
  • The Outstanding Youth Natural Science Foundation of Shandong Province (JQ201423)
  • the Jinan Clinical Medicine Science and Technology Innovation Plan (201704095)
  • National Natural Science Foundation of China (81372413, 81671785)
  • the Natural Science Foundation of Shandong province (2016ZRC03118)
  • the national key Research and Development Program of China (2016YFC0904700)
  • The Project of Invigorating Health Care through Science, Technology and Education (CXTDA2017034)

This publication has 31 references indexed in Scilit: