Novel electro-oxidation unite for electro-disinfection of E. coli and some waterborne pathogens during wastewater treatment: Batch and continuous experiments

Authors:

Abstract
This study aimed to evaluate the performance of the Novel electro-oxidation unit for the disinfection of wastewater from technoeconomic point of view. The cell was fabricated based on patent design with a total volume of 3L containing nine electrodes (6graphite and 3stainless steel) with cylindrical shape and connected to DC power supply. Determination of optimum operating parameters were investigated in batch mode on synthetic wastewater through studying effect of contact time, current density(CD), total dissolved solids concentration(TDS) and bacterial density. Also, continuous mode experiment was studied on real wastewater from agricultural drain and secondary wastewater treatment plant. The results of batch mode revealed that the optimum operational conditions that achieved the complete removal E.coli was at contact time of 5 minutes, TDS = 2000 mg/L and CD = 4mA/Cm2. Application of these conditions on the continuous mode experiment indicated the complete removal of all bacterial indicators after 5 minutes in the drainage wastewater and after 2 minutes in the secondary treated wastewater. The physico-chemical characterization indicated also, no formation of chlorine by products in the process. The electrical consumption was calculated in the continuous mode and found to be 0.5 kWh/m3 with operational cost about 0.06 $/m3 including cost of adding chemicals to increase the TDS. This proved that this novel electro-oxidation unite is cost effective for disinfection of wastewater and complete removal bacterial pollutants than other conventional treatment methods.