Improved RF performance of travelling wave MR with a high permittivity dielectric lining of the bore
- 8 October 2012
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (3) , 885-894
Abstract
Application of travelling wave MR to human body imaging is restricted by the limited peak power of the available RF amplifiers. Nevertheless, travelling wave MR advantages like a large field of view excitation and distant location of transmit elements would be desirable for whole body MRI. In this work, improvement of the efficiency of travelling wave MR is demonstrated. High permittivity dielectric lining placed next to the scanner bore wall effectively reduces attenuation of the travelling wave in the longitudinal direction and at the same time directs the radial power flow toward the load. First, this is shown with an analytical model of a metallic cylindrical waveguide with the dielectric lining next to the wall and loaded with a cylindrical phantom. Simulations and experiments also reveal an increase of efficiency in the center of the bore for travelling wave MR with a dielectric lining. Phantom experiments show up to a 2‐fold gain in with the dielectric lining. This corresponds to a 4‐fold increase in power efficiency of travelling wave MR. In vivo experiments demonstrate an 8‐fold signal‐to‐noise ratio gain with the dielectric lining. Overall, it is shown that dielectric lining is a constructive method to improve efficacy of travelling wave MR. Magn Reson Med 70:885–894, 2013.Keywords
This publication has 24 references indexed in Scilit:
- Whole body traveling wave magnetic resonance imaging at high field strength: Homogeneity, efficiency, and energy deposition as compared with traditional excitation mechanismsMagnetic Resonance in Medicine, 2011
- Clinical fMRI: Evidence for a 7T benefit over 3TNeuroImage, 2011
- Traveling‐wave RF shimming and parallel MRIMagnetic Resonance in Medicine, 2011
- SAR and power implications of different RF shimming strategies in the pelvis for 7T MRIJournal of Magnetic Resonance Imaging, 2009
- Whole‐body imaging at 7T: Preliminary resultsMagnetic Resonance in Medicine, 2008
- High‐resolution 7T MRI of the human hippocampus in vivoJournal of Magnetic Resonance Imaging, 2008
- 7 T body MRI:B1shimming with simultaneous SAR reductionPhysics in Medicine & Biology, 2007
- Analysis of wave behavior in lossy dielectric samples at high fieldMagnetic Resonance in Medicine, 2002
- Effective permittivity of mixtures: numerical validation by the FDTD methodIEEE Transactions on Geoscience and Remote Sensing, 2000
- An analytical model for the design of RF resonators for MR body imagingMagnetic Resonance in Medicine, 1991