High-resolution continuum source molecular absorption spectrometry of nitrogen monoxide and its application for the determination of nitrate
Authors:
- 1 December 2009
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 25 (2) , 163-168
Abstract
The molecular absorption spectrum of the nitrogen monoxide, NO, produced by a 5% (v/v) nitric acid solution in an air-acetylene flame has been investigated using a simultaneous, high-resolution continuum source spectrometer. The vibrational absorption bands of the electronic transition exhibit very complicated fine structure, and each band consists of a multitude of rotational absorption lines. Some of these lines have been evaluated with regard to their applicability for the determination of nitrate using electrothermal vaporization. A method has been developed, which provides a new way for the determination of nitrate. No spectral interference has been observed, mainly because of the low vaporization temperatures of only 700–900 °C, where no atomization takes place. However, hydrochloric, sulfuric and phosphoric acid, as well as metal salts, which can form acids by hydrolysis, such as Al, Cr, Cu, Fe and Mn, show strong effects and reduce the NO absorption. This kind of interference can be avoided by using a pyrolysis temperature of only 150 °C. Using the NO line 215.360 nm the limit of detection was approximately 5 ng N and the calibration curve was linear at least to 3000 ng N. The method has been validated by analyzing certified reference materials with different nitrate concentrations. The method should also be applicable to the determination of nitrite after oxidizing the nitrite to nitrate and subsequently determining the NO molecular absorption.Keywords
This publication has 30 references indexed in Scilit:
- High-resolution continuum source electrothermal absorption spectrometry of AlBr and CaBr for the determination of bromineSpectrochimica Acta Part B: Atomic Spectroscopy, 2008
- Feasibility of peak volume, side pixel and multiple peak registration in high-resolution continuum source atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2007
- Investigation of chemical modifiers for phosphorus in a graphite furnace using high-resolution continuum source atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2006
- Determination of halogens via molecules in the air–acetylene flame using high-resolution continuum source absorption spectrometry: Part I. FluorineSpectrochimica Acta Part B: Atomic Spectroscopy, 2006
- Determination of sulfur by molecular absorption of carbon monosulfide using a high-resolution continuum source absorption spectrometer and an air-acetylene flameSpectrochimica Acta Part B: Atomic Spectroscopy, 2006
- High‐Resolution Continuum Source AAS2005
- Measurements on the Zeeman-splitting of analytical lines by means of a continuum source graphite furnace atomic absorption spectrometer with a linear charge coupled device arraySpectrochimica Acta Part B: Atomic Spectroscopy, 1996
- Amperometric method for the determination of nitrate in waterAnalytica Chimica Acta, 1995
- The toxicology of nitrate, nitrite and n‐nitroso compoundsJournal of the Science of Food and Agriculture, 1975
- Bemerkungen zu der Abhandlung der HH. Weselsky und Benedikt „Ueber einige Azoverbindungen”︁European Journal of Inorganic Chemistry, 1879