In-vitro validation of a new method to assess the clinical accuracy of complete arch impressions
Open Access
- 25 February 2025
- journal article
- research article
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 29 (3) , 1-12
Abstract
Objectives: To develop and validate a new method to acquire reference distances. Materials and methods: A method to accurately register the intraoral position of precision balls was developed to generate reference values for the in-vivo assessment of impression accuracy and tested in vitro. Therefore, metal occlusal veneers with a special abutment carrying precision balls were provisionally attached to specific positions on the patient’s dental arch (anatomical model with PMMA covered metal teeth). To register the precision ball positions, form-congruent counterparts were jointed to the abutments, adhesively fixed to a transfer aid, removed and digitized with a laboratory scanner. First, the distance determination using a transfer aid and a laboratory scanner was validated. Second, the process was tested for an anatomic situation. Results: When measuring distances using a transfer aid and a laboratory scanner, distances could be detected with an accuracy of less than 5 μm. Using the new test setup on the anatomical model, the intraoral scanners more accurately reproduced scan volumes up to one quadrant, with deviations between the actual scan data sets/plaster models and the reference data set of < 52 μm for Primescan, < 82 μm for Omnicam, and < 125 μm for conventional impression. Longer distances tended to be more accurately represented by the conventional impression (Primescan < 304 μm; Omnicam < 328 μm; conventional impression < 164 μm). Conclusions: The developed method seems suitable for determining the clinical accuracy of conventional and digital complete arch impressions. Clinical relevance: For determining the clinical accuracy of conventional or digital impressions, reference values are crucial.Keywords
Funding Information
- Medizinische Fakultät Heidelberg der Universität Heidelberg
This publication has 23 references indexed in Scilit:
- Influence of operator experience, scanner type, and scan size on 3D scansThe Journal of Prosthetic Dentistry, 2021
- Effect of scan pattern on complete-arch scans with 4 digital scannersThe Journal of Prosthetic Dentistry, 2020
- Impact of different scanning strategies on the accuracy of two current intraoral scanning systems in complete-arch impressions: an in vitro study2019
- Accuracy of full-arch digital impressions: an in vitro and in vivo comparisonClinical Oral Investigations, 2019
- Accuracy evaluation of intraoral optical impressions: A clinical study using a reference applianceThe Journal of Prosthetic Dentistry, 2017
- Intraoral Scanning Systems: Need for MaintenanceThe International Journal of Prosthodontics, 2017
- A new method for assessing the accuracy of full arch impressions in patientsJournal of Dentistry, 2016
- Digital versus conventional impressions for fixed prosthodontics: A systematic review and meta-analysisThe Journal of Prosthetic Dentistry, 2016
- Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner2016
- In vivo precision of conventional and digital methods of obtaining complete-arch dental impressionsThe Journal of Prosthetic Dentistry, 2016