In situ detection of water quality contamination events based on signal complexity analysis using online ultraviolet-visible spectral sensor
Authors:
- 31 July 2017
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 56 (22) , 6317-6323
Abstract
The contaminant detection in water distribution systems is essential to protect public health from potentially harmful compounds resulting from accidental spills or intentional releases. As a noninvasive optical technique, ultraviolet-visible (UV-Vis) spectroscopy is investigated for detecting contamination events. However, current methods for event detection exhibit the shortcomings of noise susceptibility. In this paper, a new method that has less sensitivity to noise was proposed to detect water quality contamination events by analyzing the complexity of the UV-Vis spectrum series. The proposed method applied approximate entropy (ApEn) to measure spectrum signals’ complexity, which made a distinction between normal and abnormal signals. The impact of noise was attenuated with the help of ApEn’s insensitivity to signal disturbance. This method was tested on a real water distribution system data set with various concentration simulation events. Results from the experiment and analysis show that the proposed method has a good performance on noise tolerance and provides a better detection result compared with the autoregressive model and sequential probability ratio test.Keywords
Funding Information
- National Natural Science Foundation of China (NSFC) (61573313)
- Key Technology Research and Development Program of Zhejiang Province (2015C03G2010034)
This publication has 20 references indexed in Scilit:
- Distribution water quality anomaly detection from UV optical sensor monitoring data by integrating principal component analysis with chi-square distributionOptics Express, 2015
- Minimum volume ellipsoid classification model for contamination event detection in water distribution systemsEnvironmental Modelling & Software, 2014
- Contamination event detection using multiple types of conventional water quality sensors in source waterEnvironmental Science: Processes & Impacts, 2014
- A coupled classification – Evolutionary optimization model for contamination event detection in water distribution systemsWater Research, 2014
- Online Monitoring of Water-Quality Anomaly in Water Distribution Systems Based on Probabilistic Principal Component Analysis by UV-Vis Absorption SpectroscopyJournal of Spectroscopy, 2014
- Detection of water-quality contamination events based on multi-sensor fusion using an extented Dempster–Shafer methodMeasurement Science and Technology, 2013
- Use of Spectra in the Visible and Near-Mid-Ultraviolet Range with Principal Component Analysis and Partial Least Squares Processing for Monitoring of Suspended Solids in Municipal Wastewater Treatment PlantsApplied Spectroscopy, 2010
- Real-time contaminant detection and classification in a drinking water pipe using conventional water quality sensors: Techniques and experimental resultsJournal of Environmental Management, 2009
- Interpretation of Approximate Entropy: Analysis of Intracranial Pressure Approximate Entropy During Acute Intracranial HypertensionIEEE Transactions on Biomedical Engineering, 2005
- Approximate entropy as a measure of system complexity.Proceedings of the National Academy of Sciences, 1991