Interdependence of First-coil and Global volume embolization ratios (VERs) calculated by Sim&Size in predicting aneurysm occlusion outcomes
- 21 May 2025
- journal article
- Published by SAGE Publications in Interventional Neuroradiology
Abstract
Background: Coil embolization is a standard therapeutic approach for intracranial aneurysms. Recurrence risk during follow-up is not negligible, with inadequate packing density identified as a potential risk factor. This study aims to identify patient- and procedure-related factors contributing to recurrence. Methods: We retrospectively enrolled consecutive patients with unruptured intracranial aneurysms treated only with coils between January 2021 and December 2022. Aneurysms were included if 3D-rotational angiography and follow-up imaging were available. For each patient, the volume embolization ratio (VER) was computed using Sim&Size ® (Sim&Cure, France) for both the framing coil (First-coil VER) and the entire coiling procedure (Global VER). Patient demographics and aneurysm characteristics were also recorded. Follow-up imaging classified patients into adequate- or inadequate-occlusion groups. Multivariate analyses assessed independent factors associated with recurrence. Results: Seventy-nine unruptured aneurysms from 79 patients were included. At follow-up, n = 69 (87%) demonstrated adequate occlusion, defined as modified Raymond-Roy classification I-II. Adequate- and inadequate-occlusion groups differed in First-coil (13.5 ± 5.5% vs 7.1 ± 4.0% respectively, P = .002) and Global VER (24.5 ± 6.8% vs 17.3 ± 5.7% respectively, P = .004). Posterior aneurysm location ( P = .013), aneurysm height ( P = .007), and neck diameter ( P = .018) were significantly associated with recurrence. In multivariate analysis, Global- ( P = .029) and First-coil VER ( P = .025) remained significant risk factors for recurrence, with their interaction term being statistically significant as well ( P = .020). Conclusions: First-coil and Global VER computed using Sim&Size ® are predictive of aneurysm occlusion at follow-up. These results highlight the potential value of virtual simulation in optimizing coil packing density to improve mid- to long-term occlusion outcomes.Keywords
This publication has 17 references indexed in Scilit:
- Risk factors for recanalization of dense coil packing for unruptured cerebral aneurysms in endovascular coil embolization: Analysis of a single center’s experienceJournal of Clinical Neuroscience, 2022
- Patient and aneurysm factors associated with aneurysm recanalization after coilingJournal of NeuroInterventional Surgery, 2021
- Importance of the First Coil in the Embolization of Intracranial AneurysmsClinical Neuroradiology, 2018
- Risk factors for angiographic recurrence after treatment of unruptured intracranial aneurysms: Outcomes from a series of 178 unruptured aneurysms treated by regular coiling or surgeryJournal Of Neuroradiology, 2017
- Optimal first coil selection to avoid aneurysmal recanalization in endovascular intracranial aneurysmal coilingJournal of NeuroInterventional Surgery, 2017
- Effects of anatomic characteristics of aneurysms on packing density in endovascular coil embolization: analysis of a single center’s experienceNeurosurgical Review, 2015
- The relation between packing and reopening in coiled intracranial aneurysms: a prospective studyNeuroradiology, 2005
- Relation between Aneurysm Volume, Packing, and Compaction in 145 Cerebral Aneurysms Treated with CoilsRadiology, 2004
- Endovascular Treatment of Unruptured AneurysmsStroke, 2001
- Significance of Volume Embolization Ratio as a Predictor of Recanalization on Endovascular Treatment of Cerebral Aneurysms with Guglielmi Detachable CoilsInterventional Neuroradiology, 2000