Chemical-Vapor-Deposition-Based Polymer Substrates for Spatially Resolved Analysis of Protein Binding by Imaging Ellipsometry
- 12 January 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (3) , 874-880
Abstract
Biomolecular interactions between proteins and synthetic surfaces impact diverse biomedical fields. Simple, quantitative, label-free technologies for the analysis of protein adsorption and binding of biomolecules are thus needed. Here, we report the use of a novel type of substrate, poly-p-xylylene coatings prepared by chemical vapor deposition (CVD) polymerization, for surface plasmon resonance enhanced ellipsometry (SPREE) studies and assess the reactive coatings as spatially resolved biomolecular sensing arrays. Prior to use in binding studies, reactive coatings were fully characterized by Fourier transform infrared spectroscopy, electrochemical impedance spectroscopy, and ellipsometry. As a result, the chemical structure, thickness, and homogeneous coverage of the substrate surface were confirmed for a series of CVD-coated samples. Subsequent SPREE imaging and fluorescence microscopy indicated that the synthetic substrates supported detectable binding of a cascade of biomolecules. Moreover, analysis revealed a useful thickness range for CVD films in the assessment of protein and/or antigen−antibody binding via SPREE imaging. With a variety of functionalized end groups available for biomolecule immobilization and ease of patterning, CVD thin films are useful substrates for spatially resolved, quantitative binding arrays.Keywords
This publication has 58 references indexed in Scilit:
- Differential Scanning Fluorimetry Measurement of Protein Stability Changes upon Binding to Glycosaminoglycans: A Screening Test for Binding SpecificityAnalytical Chemistry, 2010
- Flow based immuno/bioassay and trends in micro-immuno/biosensorsMicrochimica Acta, 2010
- BioMEMS –Advancing the Frontiers of MedicineSensors, 2008
- Integral Geometry Analysis of Fluorescence Micrographs for Quantitative Relative Comparison of Protein Adsorption onto Polymer SurfacesLangmuir, 2008
- Foreign body reaction to biomaterialsSeminars in Immunology, 2008
- Pretreatment plasma fibrinogen level correlates with tumor progression and metastasis in patients with squamous cell carcinoma of the esophagusJournal of Gastroenterology and Hepatology, 2007
- Photoinduced Transformations in Bacteriorhodopsin Membrane Monitored with Optical MicrocavitiesBiophysical Journal, 2007
- Growth Factor Mediated Assembly of Cell Receptor-Responsive HydrogelsJournal of the American Chemical Society, 2007
- Reactive Polymer Coatings that “Click”Angewandte Chemie International Edition, 2006
- Novel Poly(p-xylylenes): Thin Films with Tailored Chemical and Optical PropertiesMacromolecules, 2002