Safety and Efficacy of GreenLight XPS Laser Vapoenucleation in Prostates Measuring Over 150 mL
Authors:
- 1 August 2016
- journal article
- research article
- Published by SAGE Publications in Journal of Endourology
- Vol. 30 (8) , 906-912
Abstract
Introduction: The GreenLight™ XPS Laser System (GL-XPS) is a safe and efficacious treatment for lower urinary tract symptoms due to benign prostatic hyperplasia (BPH), but there is limited evidence on its use in prostates over 150 mL. We demonstrate the safety and efficacy of the GL-XPS system using a vapoenucleation technique in prostate glands measuring over 150 mL. Methods: We prospectively collected data on all consecutive patients with prostates measuring over 150 mL on transrectal ultrasound treated with the GL-XPS (AMS, Inc., Minnetonka, MN) at a tertiary referral center from September 2011 to October 2015. Data collected include prostate volume, International Prostate Symptom Score (IPSS) and quality of life (QoL) scores, maximum urinary flow rate (Qmax), postvoid residual (PVR), prostate-specific antigen, complications, and reintervention rates. Results: Seventy male patients with a median prostate size of 202 mL (range 152–376 mL) were included. There were 41 patients (59%) in preoperative urinary retention with an indwelling catheter preoperatively. Thirty-seven (53%) patients were American Society of Anesthesiologists (ASA) class 2 and 33 (47%) were class 3. Median operative time was 180 minutes, laser time 97 minutes, energy utilization 674 kJ, and energy density 3.3 kJ/mL, with median 3 fibers used per case. Median length of stay and length of catheterization were 1 day. IPSS and QoL scores demonstrated significant improvements from baseline at all endpoints, improving from 16 to 3.5 and from 4 to 1 at 24 months, respectively (p = 0.001). At 12 months, Qmax and PVR improved from 10.1 to 22.4 mL/s (p = 0.043) and from 84 to 31.4 mL (p = 0.015), respectively. Retreatment was required in two patients (2.9%). Conclusion: GL-XPS vapoenucleation provided durable subjective and objective improvements in symptoms and voiding parameters, with no serious adverse events in men with prostates >150 mL.Keywords
This publication has 27 references indexed in Scilit:
- A Multicenter Randomized Noninferiority Trial Comparing GreenLight-XPS Laser Vaporization of the Prostate and Transurethral Resection of the Prostate for the Treatment of Benign Prostatic Obstruction: Two-yr Outcomes of the GOLIATH StudyEuropean Urology, 2016
- A European Multicenter Randomized Noninferiority Trial Comparing 180 W GreenLight XPS Laser Vaporization and Transurethral Resection of the Prostate for the Treatment of Benign Prostatic Obstruction: 12-Month Results of the GOLIATH StudyJournal of Urology, 2015
- EAU Guidelines on the Treatment and Follow-up of Non-neurogenic Male Lower Urinary Tract Symptoms Including Benign Prostatic ObstructionEuropean Urology, 2013
- Does Size Really Matter? The Impact of Prostate Volume on the Efficacy and Safety of GreenLight HPS™ Laser Photoselective Vaporization of the ProstateJournal of Endourology, 2012
- Update on AUA Guideline on the Management of Benign Prostatic HyperplasiaJournal of Urology, 2011
- Meta-analysis of Functional Outcomes and Complications Following Transurethral Procedures for Lower Urinary Tract Symptoms Resulting from Benign Prostatic EnlargementEuropean Urology, 2010
- Holmium Laser Enucleation of Prostate: Outcome and Complications of Self-taught Learning CurveUrology, 2009
- Transurethral Photoselective Vaporization versus Transvesical Open Enucleation for Prostatic Adenomas >80ml: 12-mo Results of a Randomized Prospective StudyEuropean Urology, 2008
- Holmium Laser Enucleation of the Prostate versus Open Prostatectomy for Prostates Greater than 100 Grams: 5-Year Follow-Up Results of a Randomised Clinical TrialEuropean Urology, 2008
- Holmium Laser Enucleation of the Prostate for Glands Larger than 100 g: An Endourologic Alternative to Open ProstatectomyJournal of Endourology, 2000