A carbon CT system: how to obtain accurate stopping power ratio using a Bragg peak reduction technique
Authors:
- 31 January 2018
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (3) , 035025
Abstract
In this study, we investigate the performance of the Gunma University Heavy Ion Medical Center’s ion computed tomography (CT) system, which measures the residual range of a carbon-ion beam using a fluoroscopy screen, a charge-coupled-device camera, and a moving wedge absorber and collects CT reconstruction images from each projection angle. Each 2D image was obtained by changing the polymethyl methacrylate (PMMA) thickness, such that all images for one projection could be expressed as the depth distribution in PMMA. The residual range as a function of PMMA depth was related to the range in water through a calibration factor, which was determined by comparing the PMMA-equivalent thickness measured by the ion CT system to the water-equivalent thickness measured by a water column. Aluminium, graphite, PMMA, and five biological phantoms were placed in a sample holder, and the residual range for each was quantified simultaneously. A novel method of CT reconstruction to correct for the angular deflection of incident carbon ions in the heterogeneous region utilising the Bragg peak reduction (BPR) is also introduced in this paper, and its performance is compared with other methods present in the literature such as the decomposition and differential methods. Stopping power ratio values derived with the BPR method from carbon-ion CT images matched closely with the true water-equivalent length values obtained from the validation slab experiment.Keywords
This publication has 24 references indexed in Scilit:
- Beam commissioning of a superconducting rotating-gantry for carbon-ion radiotherapyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Effect of tissue heterogeneity on anin vivorange verification technique for proton therapyPhysics in Medicine & Biology, 2012
- Nonlinear backprojection for tomographic reconstructionIEEE Transactions on Nuclear Science, 2002
- Performance of a fluorescent screen and CCD camera as a two-dimensional dosimetry system for dynamic treatment techniquesMedical Physics, 2000
- Computed tomography using proton energy lossPhysics in Medicine & Biology, 1981
- Treatment planning for heavy ion radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1979
- Some practical remarks on multiple scatteringNuclear Instruments and Methods, 1975
- Three-dimensional density reconstruction from a series of two-dimensional projectionsNuclear Instruments and Methods, 1972
- Representation of a Function by Its Line Integrals, with Some Radiological Applications. IIJournal of Applied Physics, 1964
- Representation of a Function by Its Line Integrals, with Some Radiological ApplicationsJournal of Applied Physics, 1963