Sensitive Determination of Cannabinoids in Whole Blood by LC–MS-MS After Rapid Removal of Phospholipids by Filtration
- 17 April 2017
- journal article
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 41 (5) , 382-391
Abstract
Direct analysis of Δ9-tetrahydrocannabinol (THC) and other cannabinoids in crude acetonitrile extracts of whole blood by liquid chromatography–tandem mass spectrometry using pneumatically assisted electrospray ionization (LC–ESI–MS-MS) was subjected to pronounced ion suppression from co-eluting phospholipids (PLs). The interferences were mainly caused by the lysophosphatidylcholine and lysophosphatidylethanolamine classes of PLs. The PLs were easily removed from crude extracts by filtration through a sorbent with Lewis acid properties, which typically increased the THC and cannabinol (CBN) signal intensities by a factor of 5. Based on this technique, a simple high-throughput LC–MS-MS method was developed for the determination of cannabinoids in 100 μL samples of whole blood. The lower limits of quantification were 0.2 μg/L for THC, CBN, cannabidiol (CBD) and Δ9-tetrahydrocannabinolic acid A (THCA-A) and 0.5 μg/L for 11-hydroxy-Δ9-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH). The mean ion suppression levels after clean-up were 10% (THC), 9% (CBN), 17% (CBD), 0% (THC-OH), 2% (THC-COOH) and 9% (THCA-A) at blood concentration levels of 1–10 μg/L. The mean true extraction recoveries were 97% (THC), 101% (CBN), 101% (CBD), 98% (THC-OH), 95% (THC-COOH) and 90% (THCA-A) at the same concentration levels. The relative intra-laboratory reproducibility standard deviations were <9% at concentrations of 1 μg/L or higher. The trueness expressed as the relative bias of the test results was within ±4% at concentrations of 1 μg/L or higher.Keywords
This publication has 26 references indexed in Scilit:
- Determination of the relative percentage distribution of THCA and Δ9-THC in herbal cannabis seized in Austria – Impact of different storage temperatures on stabilityForensic Science International, 2015
- On-line SPE LC-MS/MS for the quantification of Δ9-tetrahydrocannabinol (THC) and its two major metabolites in human peripheral blood by liquid chromatography tandem mass spectrometryAnalytical and Bioanalytical Chemistry, 2011
- The Frequency of Drugs Among Danish Drivers Before and After the Introduction of Fixed Concentration LimitsTraffic Injury Prevention, 2010
- Solid-phase extraction and analysis of THC and carboxy-THC from whole blood using a novel fluorinated solid-phase extraction sorbent and fast liquid chromatography-tandem mass spectrometry.Journal of Analytical Toxicology, 2009
- A semi‐automated solid‐phase extraction liquid chromatography/tandem mass spectrometry method for the analysis of tetrahydrocannabinol and metabolites in whole bloodRapid Communications in Mass Spectrometry, 2009
- Simultaneous analysis of THC and its metabolites in blood using liquid chromatography–tandem mass spectrometryJournal of Chromatography B, 2008
- Tetrahydrocannabinol and two of its metabolites in whole blood using liquid chromatography-tandem mass spectrometry.Journal of Analytical Toxicology, 2008
- Determination of Cannabinoids in Whole Blood by UPLC-MS-MSJournal of Analytical Toxicology, 2008
- Validated method for the simultaneous determination of Δ9-THC and Δ9-THC-COOH in oral fluid, urine and whole blood using solid-phase extraction and liquid chromatography–mass spectrometry with electrospray ionizationForensic Science International, 2007
- Isolation of Δ9-THCA-A from hemp and analytical aspects concerning the determination of Δ9-THC in cannabis productsForensic Science International, 2005