The Chest Radiograph in Critically Ill Surgical Patients is Inaccurate in Predicting Ventilator-Associated Pneumonia
Authors:
- 1 September 1999
- journal article
- Published by SAGE Publications in The American Surgeon™
- Vol. 65 (9) , 805-810
Abstract
Chest radiographs (CXRs) are frequently obtained in surgical intensive care unit (SICU) patients when a diagnosis of ventilator-associated pneumonia (VAP) is suspected. The purpose of this study was to determine if the interpretation of the CXR correlated with a diagnosis of VAP in SICU patients. Prospective evaluation of 20 SICU patients clinically suspected of VAP was performed from July 1997 through December 1998. All patients required mechanical ventilation for at least 48 hours, and antibiotic use was discontinued 24 hours before entry into the study. Bronchoscopy with protected specimen brush (PSB) sampling of secretions from the right and left lung was performed. A positive PSB was present if quantitative analysis yielded ≥10 4 colony-forming units/mL of bacteria. VAP was diagnosed if either the right or left PSB was positive and ruled-out if both the right and left PSB yielded 4 colony-forming units/mL. Twelve of 20 patients (60%) were diagnosed to have VAP by PSB criteria. Eight of 20 patients (40%) had CXRs interpreted as negative for infiltrates; four patients had VAP by PSB criteria. There were four patients with focal infiltrates; two patients had VAP. The remaining eight patients had radiographs interpreted as bilateral infiltrates (one) or pulmonary edema (seven); of these, six patients (75%) had VAP. The sensitivity of the CXR in determining the presence of VAP was 25 per cent, the specificity was 75 per cent, and the accuracy was 0.45. The CXR does not improve the clinician's ability to diagnose VAP: a normal CXR does not exclude the presence of VAP and the finding of a focal infiltrate does not confirm the diagnosis of VAP.Keywords
This publication has 14 references indexed in Scilit:
- Impact of BAL Data on the Therapy and Outcome of Ventilator-Associated PneumoniaChest, 1997
- Comparison of Nonbronchoscopic Techniques with Bronchoscopic Brushing in the Diagnosis of Ventilator-Associated PneumoniaThe Journal of Trauma: Injury, Infection, and Critical Care, 1996
- Problems in diagnosing nosocomial pneumonia in mechanically ventilated patients: A reviewCritical Care Medicine, 1994
- Evaluation of Clinical Judgment in the Identification and Treatment of Nosocomial Pneumonia in Ventilated PatientsChest, 1993
- Protected Specimen Brush in the Assessment of Ventilator-Associated PneumoniaChest, 1993
- The Radiologic Diagnosis of Autopsyproven Ventilator-associated PneumoniaChest, 1992
- Incidence, Etiology, and Outcome of Nosocomial Pneumonia in Mechanically Ventilated PatientsChest, 1991
- Reliability of the bronchoscopic protected catheter brush in the diagnosis of pneumonia in mechanically ventilated patientsCritical Care Medicine, 1991
- Incidence, Risk, and Prognosis Factors of Nosocomial Pneumonia in Mechanically Ventilated PatientsAmerican Review of Respiratory Disease, 1990
- Diagnostic Value of Telescoping Plugged Catheters in Mechanically Ventilated Patients with Bacterial Pneumonia Using the Metras CatheterAmerican Review of Respiratory Disease, 1988