A Novel Detection of Enterococcus faecalis Using Multiple Cross Displacement Amplification Linked with Gold Nanoparticle Lateral Flow Biosensor
Open Access
- 1 December 2019
- journal article
- research article
- Published by Taylor & Francis in Infection and Drug Resistance
- Vol. ume 12, 3771-3781
Abstract
Background: Enterococcus faecalis, an opportunistic bacterial pathogen, is one of the most frequently isolated bacterial species and cause of serious nosocomial infections in recent decades. A reliable and rapid assay for E. faecalis detection is significant for the diagnosis and follow-up treatment. Methods: A novel assay method, named multiple cross displacement amplification linked with nanoparticle-based lateral flow biosensor (MCDA-LFB), was applied for detecting E. faecalis strains. A set of special 10 primers was designed according to E. faecalis-specific gene Ef0027. The MCDA amplification conditions, including the target DNA concentration, reaction temperature and time, were optimized. The sensitivity and specificity of MCDA method were tested in the current study, and then, the MCDA-LFB technology was applied to detect the E. faecalis strain from clinical samples. Results: The E. faecalis specific primers were valid for the establishment of MCDA-LFB technology forthe detection of E. faecalis based on the Ef0027 gene. The MCDA amplification condition was optimized at 62°C for 35 min. The MCDA products were directly sensed and displayed with a biosensor. The full process, comprising genomic DNA template preparation (approximately 30 mins), amplification of MCDA (35 mins), and the product identification (approximately 2 mins), could be achieved in 70 mins. The MCDA technique could detect as little as 10 fg per reaction system of pure E. faecalis genomic DNA. The specificity of E. faecalis-MCDA-LFB method is 100%, with no cross-reactions to non-E. faecalis strains. Conclusion: The MCDA-LFB technique established in the present study is a reliable, simple, rapid, sensitive and specific method to assay E. faecalis and can be applied for the detection of clinical samples.Keywords
This publication has 28 references indexed in Scilit:
- Evaluation of Phage Therapy in the Context of Enterococcus faecalis and Its Associated DiseasesViruses, 2019
- Isothermal amplification and rapid detection of Klebsiella pneumoniae based on the multiple cross displacement amplification (MCDA) and gold nanoparticle lateral flow biosensor (LFB)PLOS ONE, 2018
- A Review of Combination Antimicrobial Therapy for Enterococcus faecalis Bloodstream Infections and Infective EndocarditisClinical Infectious Diseases, 2018
- Nanoparticle-based lateral flow biosensor combined with multiple cross displacement amplification for rapid, visual and sensitive detection of Vibrio choleraeFEMS Microbiology Letters, 2017
- High Incidence of Virulence Factors Among ClinicalEnterococcus faecalisIsolates in Southwestern IranInfection & Chemotherapy, 2017
- Evaluation of Antibacterial Efficacy of Photodynamic Therapy vs. 2.5% NaOCl against E. faecalis-infected Root Canals Using Real-time PCR TechniqueJournal of Clinical and Experimental Dentistry, 2017
- Development of multiple cross displacement amplification label-based gold nanoparticles lateral flow biosensor for detection of Listeria monocytogenesInternational Journal of Nanomedicine, 2017
- Multiple Cross Displacement Amplification Combined with Gold Nanoparticle-Based Lateral Flow Biosensor for Detection of Vibrio parahaemolyticusFrontiers in Microbiology, 2016
- Multiplex, Rapid, and Sensitive Isothermal Detection of Nucleic-Acid Sequence by Endonuclease Restriction-Mediated Real-Time Multiple Cross Displacement AmplificationFrontiers in Microbiology, 2016
- The Type I toxin–antitoxin par locus from Enterococcus faecalis plasmid pAD1: RNA regulation by both cis- and trans-acting elementsPlasmid, 2014