Abstract
To monitor corneal structures with slitlamp-adapted optical coherence tomography (OCT) in laser in situ keratomileusis (LASIK). Department of Ophthalmology, Vivantes Klinikum Neukölln, Berlin, Germany. In this prospective, nonrandomized, comparative clinical case series of consecutive patients who had LASIK for myopia and myopic astigmatism, the corneal structures were studied with slitlamp-adapted OCT at a wavelength of 1,310 nm. The central corneal thickness (CCT) and epithelial, flap, and residual stromal thicknesses were assessed preoperatively, immediately after surgery, on postoperative day 1, and then, on average, after 8, 35, and 160 days. Twenty-five eyes of 13 patients were included. The attempted mean spherical equivalent correction was -6.11 diopters (D) +/- 2.16 (SD) with a mean calculated stromal ablation depth of 92 +/- 24 microm. The CCT was 516 +/- 26 microm preoperatively and 453 +/- 40 microm postoperatively (P<.001). The epithelial thickness increased from 57.0 +/- 7.7 microm preoperatively to 61.0 +/- 7.5 microm postoperatively (P =.04). Imaging of the hyperreflective interface was possible in all patients for up to 15 months. The flap and residual stromal thickness was 211 +/- 28 microm and 344 +/- 48 microm, respectively, immediately after LASIK and 164 +/- 21 microm (P<.001) and 284 +/- 32 microm (P<.001), respectively, on postoperative day 1. There were no further significant changes during the follow-up. The overall mean reproducibility was +/-4.50 microm (coefficient of variation [CV] 0.94%) for CCT, +/-4.99 microm (CV 8.57%) for epithelial thickness, +/-6.25 microm (CV 3.55%) for flap thickness, and +/-7.09 microm (CV 2.42%) for residual stromal thickness. Slitlamp-adapted OCT can be used to longitudinally monitor the variable structures of the cornea, epithelium, flap, and residual stroma in LASIK.Keywords
This publication has 43 references indexed in Scilit:
- Risk factors and prognosis for corneal ectasia after LASIKOphthalmology, 2003
- Laser in situ keratomileusis for myopia and astigmatism: safety and efficacyOphthalmology, 2002
- Corneal ectasia induced by laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2001
- Corneal ectasia after laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2001
- The predictability of corneal flap thickness and tissue laser ablation in laser in situ keratomileusisOphthalmology, 2000
- Iatrogenic keratectasia after laser in situ keratomileusis for less than −4.0 to −7.0 diopters of myopiaJournal of Cataract & Refractive Surgery, 2000
- Delayed onset keratectasia following laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 1999
- Iatrogenic keratectasia after LASIK in a case of forme fruste keratoconusJournal of Cataract & Refractive Surgery, 1998
- Mathematics of laser in situ keratomileusis for high myopiaJournal of Cataract & Refractive Surgery, 1998
- Laser in situ keratomileusis to correct high myopiaJournal of Cataract & Refractive Surgery, 1997