Comparison of anterior segment optical coherence tomography and ultrasound biomicroscopy for assessment of the anterior segment
- 1 May 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 33 (5) , 837-840
Abstract
To compare anterior segment parameters using quantitative imaging by anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM). Tertiary-care glaucoma research center. Sixty-three eyes of 63 subjects had anterior segment evaluation by AS-OCT (Visante-Zeiss) and UBM (Paradigm). Central corneal thickness (CCT), anterior chamber depth (ACD) (measured from the central corneal endothelium to the anterior lens capsule), and the peripheral iridocorneal angles (temporal and nasal) were assessed and compared. There was an excellent correlation between AS-OCT and UBM measurements for the nasal angle (r = 0.84; P<.0001), temporal angle (r = 0.86; P<.0001), ACD (r = 0.97; P<.0001), and CCT (r = 0.91; P<.0001). There was no significant difference (paired t test) between the mean ACD, CCT, and angle parameters measured by AS-OCT or UBM. The mean values of the parameters measured by AS-OCT and UBM were, respectively, as follows: nasal angle, 26.25 degrees +/- 11.0 (SD) and 28.27 +/- 11.3 degrees (P = .3); temporal angle, 25.1 +/- 11.4 degrees and 28.3 +/- 13.5 degrees (P = .15); ACD, 2.85 +/- 0.5 mm and 2.78 +/- 0.5 mm (P = .2); and CCT, 512 +/- 46 microm and 502 +/- 46 microm (P = .25). The AS-OCT images showed sharper definition of the scleral spur than the UBM images. Anterior segment optical coherence tomography and UBM can both be used for anterior segment measurements and yielded comparable results.Keywords
This publication has 14 references indexed in Scilit:
- Comparison of Optical Coherence Tomography and Ultrasound Biomicroscopy for Detection of Narrow Anterior Chamber AnglesArchives of Ophthalmology (1950), 2005
- Noncontact Goniometry With Optical Coherence TomographyArchives of Ophthalmology (1950), 2005
- Anterior chamber width measurement by high-speed optical coherence tomographyOphthalmology, 2005
- Noncontact Measurements of Central Corneal Epithelial and Flap Thickness after Laser In Situ KeratomileusisInvestigative Ophthalmology & Visual Science, 2004
- Optische Kohärenztomographie versus Ultraschallbiomikroskopie bei Bindehaut- und LidtumorenKlinische Monatsblätter für Augenheilkunde, 2003
- Ultraschallbiomikroskopie bei BindehauttumorenKlinische Monatsblätter für Augenheilkunde, 2003
- Real-Time Optical Coherence Tomography of the Anterior Segment at 1310 nmArchives of Ophthalmology (1950), 2001
- Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence TomographyArchives of Ophthalmology (1950), 1994
- Ultrasound Biomicroscopy of Anterior Segment Structures in Normal and Glaucomatous EyesAmerican Journal of Ophthalmology, 1992
- Subsurface Ultrasound Microscopic Imaging of the Intact EyeOphthalmology, 1990