Trace gas detection of molecular hydrogen H2 by photoacoustic stimulated Raman spectroscopy (PARS)
Authors:
- 2 February 2012
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 137 (6) , 1384-1388
Abstract
Photoacoustic stimulated Raman spectroscopy (PARS) has been used for sensitive and selective trace gas detection of molecular hydrogen under ambient conditions. In one experiment, 532 nm output of a seeded pulsed Nd:YAG laser is employed as Raman pump source and a Raman shifter filled with gaseous H2 to obtain Stokes shifted radiation at 683 nm, suitable to stimulate H2 Raman detection in a photoacoustic cell. A noise equivalent detection limit of 40 ppm by volume H2 in 1 atm N2 is obtained (14 mJ at 532 nm, 18 mJ at 683 nm, 10 Hz repetition rate, 58 s measurement time). Another experiment employs a dye laser for stimulating Raman radiation between 681–684 nm, allowing tuneable PARS. A Gaussian spectral fitting procedure has been applied giving a noise equivalent detection limit of 4.6 ppm by volume H2 in 1 atm N2 (35 mJ pulse energy at 532 nm, 45 mJ at 681–684 nm, 10 Hz repetition rate, 256 s measurement time). Spectroscopic detection offers the advantage of high selectivity along with the ability to obtain temperature and dynamic information from the rotational population and a line shape analysis, and also allows the discrimination between ortho- and para-H2.Keywords
This publication has 16 references indexed in Scilit:
- Hydrogen sensors – A reviewSensors and Actuators B: Chemical, 2011
- A novel demonstration of photoacoustic Raman spectroscopy with combined stimulated Raman pumping in H2 moleculeOptics Communications, 2009
- A small mass spectrometer system for in situ gas analysisTrAC Trends in Analytical Chemistry, 2004
- Hydrogen economy for a sustainable development: state-of-the-art and technological perspectivesJournal of Power Sources, 2001
- Application of acoustic resonators in photoacoustic trace gas analysis and metrologyReview of Scientific Instruments, 2001
- Nonlinear Raman spectroscopy without tunable laser for sensitive gas detection in the atmosphereOptics Communications, 1999
- Sensitive H 2 Detection Using a New Technique of Photoacoustic Raman SpectroscopyJapanese Journal of Applied Physics, 1997
- Whitney Award Lecture—1987: Hydrogen—The Versatile EmbrittlerCorrosion, 1987
- Temperature dependence of the Raman linewidth and line shift for the Q(1) and Q(0) transitions in normal and para-Physical Review A, 1986
- The Lyman and Werner bands of H2Canadian Journal of Physics, 1984