Blood Flow in Stented Arteries: A Parametric Comparison of Strut Design Patterns in Three Dimensions
Authors:
- 10 February 2005
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 127 (4) , 637-647
Abstract
Background: Restenosis after stent implantation varies with stent design. Alterations in secondary flow patterns and wall shear stress (WSS) can modulate intimal hyperplasia via their effects on platelet and inflammatory cell transport toward the wall, as well as direct effects on the endothelium. Method of Approach: Detailed flow characteristics were compared by estimating the WSS in the near-strut region of realistic stent designs using three-dimensional computational fluid dynamics (CFD), under pulsatile high and low flow conditions. The stent geometry employed was characterized by three geometric parameters (axial strut pitch, strut amplitude, and radius of curvature), and by the presence or lack of the longitudinal connector. Results: Stagnation regions were localized around stent struts. The regions of low WSS are larger distal to the strut. Under low flow conditions, the percentage restoration of mean axial WSS between struts was lower than that for the high flow by 10–12%. The largest mean transverse shear stresses were 30–50% of the largest mean axial shear stresses. The percentage restoration in WSS in the models without the longitudinal connector was as much as 11% larger than with the connector. The mean axial WSS restoration between the struts was larger for the stent model with larger interstrut spacing. Conclusion: The results indicate that stent design is crucial in determining the fluid mechanical environment in an artery. The sensitivity of flow characteristics to strut configuration could be partially responsible for the dependence of restenosis on stent design. From a fluid dynamics point of view, interstrut spacing should be larger in order to restore the disturbed flow; struts should be oriented to the flow direction in order to reduce the area of flow recirculation. Longitudinal connectors should be used only as necessary, and should be parallel to the axis. These results could guide future stent designs toward reducing restenosis.Keywords
This publication has 26 references indexed in Scilit:
- Stent design properties and deployment ratio influence indexes of wall shear stress: a three-dimensional computational fluid dynamics investigation within a normal arteryJournal of Applied Physiology, 2004
- Clinical impact of stent construction and design in percutaneous coronary interventionAmerican Heart Journal, 2004
- Response of very small (2 mm) porcine coronary arteries to balloon angioplasty and stent implantationHeart, 2004
- Augmentation of Wall Shear Stress Inhibits Neointimal Hyperplasia After Stent ImplantationCirculation, 2003
- Fluid Mechanics of Vascular Systems, Diseases, and ThrombosisAnnual Review of Biomedical Engineering, 1999
- Intravascular Ultrasound Predictors of Angiographic Restenosis in Lesions Treated With Palmaz-Schatz StentsJACC, 1998
- Fluid wall shear stress measurements in a model of the human abdominal aorta: oscillatory behavior and relationship to atherosclerosisAtherosclerosis, 1994
- Changes in arterial wall compliance after endovascular stentingJournal of Vascular Surgery, 1994
- Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress.Arteriosclerosis: An Official Journal of the American Heart Association, Inc., 1985
- Adhesion of human platelets to collagen on the walls distal to a tubular expansionMicrovascular Research, 1979