Dynamic Amplification Factor Measuring of T-Girder Bridges
Authors:
- 1 January 2013
- journal article
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 540, 29-36
Abstract
Field measurement was conducted on the evaluation of dynamic amplification factors (DAF) for four existing T-girder bridges. Both ambient vibration testing and vehicle impact testing were carried out on the bridges. Ambient vibration testing is relatively easier to conduct and can provide detailed vibrating information of the structure. However vehicle impact testing is indispensable to obtain the impact factor of the traffic load. The measured vibration frequencies matched well to those of calculated values. This means that the finite element model may enable good predictions of the actual behavior of the bridge. The measured DAF for these bridges located in the interval [1.05, 1.22].Keywords
This publication has 4 references indexed in Scilit:
- Steel, concrete and composite bridges2013
- Characteristic dynamic traffic load effects in bridgesEngineering Structures, 2009
- Evaluation of dynamic loads on a skew box girder continuous bridge Part I: Field test and modal analysisEngineering Structures, 2007
- Bridge dynamics and dynamic amplification factors — a review of analytical and experimental findingsCanadian Journal of Civil Engineering, 1992