An experimental investigation of the ac-losses in high-current strands and cables
Authors:
- 19 August 1998
- journal article
- research article
- Published by Taylor & Francis in Plasma Devices and Operations
- Vol. 6 (4) , 345-352
Abstract
The paper presents the results obtained during the AC-losses measurements of the ITER strands and subsize cable samples. The test facility and samples are described. The method of investigation is based on both the calorimeter application and magnetization loop recording. The coincidence of their results is considered. The original calorimeter scheme allows to measure the energy dissipated during one pulse of the field variation.Keywords
This publication has 2 references indexed in Scilit:
- First results of a parametric study on coupling loss in subsize NET/ITER Nb/sub 3/Sn cabled specimenIEEE Transactions on Applied Superconductivity, 1995
- Losses in superconducting composites under high rate pulsed transverse fieldIEEE Transactions on Magnetics, 1979