PULSED EDDY CURRENT PROBE DESIGN BASED ON TRANSIENT CIRCUIT ANALYSIS

Authors:
  • DTDonald O. Thompson
    Donald O. Thompson
  • DCDale E. Chimenti
    Dale E. Chimenti

Abstract
Probe design parameters affecting depth of penetration of pulsed eddy currents in multi‐layer aluminum 2024‐T3 were examined. Several probe designs were evaluated for their ability to detect a discontinuity at the bottom of a stack of aluminum plates. The reflection type probes, consisting of pick‐up coil and encircling drive coil, were characterized based on their transient response to a square pulse excitation. Probes with longer fundamental time constants, equivalent to a lower driving frequency, generated greater depth of penetration. However, additional factors such as inductive and resistive load, and excessive coil heating were also factors that limited signal‐to‐noise response with increasing layer thickness.