Are Accuracy Studies for Periprosthetic Joint Infection Diagnosis Inherently Flawed? And What to Do with Schrödinger’s Hips? A Prospective Analysis of the Alpha Defensin Lateral-Flow Test in Chronic Painful Hip Arthroplasties
Open Access
- 1 January 2022
- journal article
- research article
- Published by The Korean Hip Society in Hip & Pelvis
- Vol. 34 (4) , 236-244
Abstract
The most recent diagnostic criteria for periprosthetic joint infection (PJI) include the use of the alpha-defensin (AD) lateral-flow (LF) test, but hip and knee arthroplasties were usually combined in previous studies. This prospective study was designed to examine the accuracy of the AD-LF test for diagnosis of PJI in chronic painful total hip arthroplasties (THA). Patients with chronic painful hip arthroplasties were prospectively enrolled between March 2018 and May 2020. Exclusion criteria included acute PJI or an insufficient amount of synovial fluid. The modified Musculoskeletal Infection Society (MSIS) criteria were primarily used for PJI diagnosis. Fifty-seven patients were included in the analysis group. Revision surgery was not performed in 38 patients, for different reasons (clinical group); these patients remain "Schrödinger's hips": in such cases PJI cannot be excluded nor confirmed until you "open the box". The result of the AD-LF test was positive in nine patients and negative in 48 patients. Six patients were diagnosed with PJI. AD-LF sensitivity (MSIS criteria) was 83% (95% confidence interval [CI] 36-100%) and specificity was 92% (95% CI 81-98%). The positive and negative predictive value were 56% and 98%, respectively. The AD test is useful in addition to the existing arsenal of diagnostic tools, and can be helpful in the decision-making process. Not all patients with chronical painful THA will undergo revision surgery. Consequently, in order to determine the reliable diagnostic accuracy of this test, future PJI diagnostic studies should include a second arm of "Schrödinger's hips".Keywords
This publication has 15 references indexed in Scilit:
- The Alpha-Defensin Test for Diagnosing Periprosthetic Joint Infection in the Setting of an Adverse Local Tissue Reaction Secondary to a Failed Metal-on-Metal Bearing or Corrosion at the Head-Neck JunctionThe Journal of Arthroplasty, 2018
- The unsuspected prosthetic joint infectionThe Bone & Joint Journal, 2017
- High performance of α-defensin lateral flow assay (Synovasure) in the diagnosis of chronic knee prosthetic infectionsKnee Surgery, Sports Traumatology, Arthroscopy, 2017
- The Alpha-defensin Test for Periprosthetic Joint Infections Is Not Affected by Prior Antibiotic AdministrationClinical Orthopaedics and Related Research, 2016
- How Reliable Is the Alpha-defensin Immunoassay Test for Diagnosing Periprosthetic Joint Infection? A Prospective StudyClinical Orthopaedics and Related Research, 2016
- Combined Measurement of Synovial Fluid α-Defensin and C-Reactive Protein Levels: Highly Accurate for Diagnosing Periprosthetic Joint InfectionJournal of Bone and Joint Surgery, 2014
- Diagnosis of Periprosthetic Joint InfectionJournal of Orthopaedic Research, 2014
- New Definition for Periprosthetic Joint Infection: From the Workgroup of the Musculoskeletal Infection SocietyClinical Orthopaedics and Related Research, 2011
- Evaluation of diagnostic tests when there is no gold standard. A review of methodsHealth Technology Assessment, 2007
- The Impact of Infection After Total Hip Arthroplasty on Hospital and Surgeon Resource UtilizationJournal of Bone and Joint Surgery, 2005