Microchip Capillary Electrophoresis Coupled with a Boron-Doped Diamond Electrode-Based Electrochemical Detector
Authors:
- Joseph WangJWJoseph Wang
- Gang ChenGCGang Chen
- Madhu Prakash ChatrathiMCMadhu Prakash Chatrathi
- Akira FujishimaAFAkira Fujishima
- Donald A. TrykDonald A. Tryk
- Dongchan ShinDSDongchan Shin
- 14 January 2003
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (4) , 935-939
Abstract
The attractive behavior and advantages of a diamond electrode detector for a micromachined capillary electrophoresis (CE) system are discussed. A chemically vapor-deposited boron-doped diamond (BDD) film band (0.3 × 6.0 mm) electrode is used for end-column amperometric detection. The favorable performance of the diamond electrode microchip detector is indicated from comparison to a commonly used thick-film carbon detector. The diamond electrode offers enhanced sensitivity, lower noise levels, and sharper peaks for several groups of important analytes (nitroaromatic explosives, organophosphate nerve agents, phenols). The favorable signal-to-background characteristics of the BDD-based CE detector are coupled with a greatly improved resistance to surface fouling and greater isolation from high separation voltages. The enhanced stability is indicated from a RSD of 0.8% for 60 repetitive measurements of 5 ppm 2,4,6-trinitrotoluene (vs RSD of 10.8% at the thick-film carbon electrode). A highly linear response is obtained for the explosives 1,3-dinitrobenzene and 2,4-dinitrotoluene over the 200−1400 ppb range, with detection limits of 70 and 110 ppb, respectively. Factors influencing the performance of the BDD detector are assessed and optimized. The attractive properties of BDD make it very promising material for electrochemical detection in CE microchip systems and other micromachined flow analyzers.Keywords
This publication has 23 references indexed in Scilit:
- Electrochemical analysis of nucleic acids at boron-doped diamond electrodesThe Analyst, 2002
- Direct cytochrome c electrochemistry at boron-doped diamond electrodesElectrochemistry Communications, 2002
- Electrochemical Glucose Detection Using Nickel-Implanted Boron-Doped Diamond ElectrodesElectrochemical and Solid-State Letters, 2002
- Voltammetric Determination ofl-Cysteine at Conductive Diamond ElectrodesAnalytical Chemistry, 2001
- Lab-on-a-Chip: A Revolution in Biological and Medical Sciences.Analytical Chemistry, 2000
- Micromachined Electrophoresis Chips with Thick-Film Electrochemical DetectorsAnalytical Chemistry, 1999
- Integrated Electrophoresis Chips/Amperometric Detection with Sputtered Gold Working ElectrodesAnalytical Chemistry, 1999
- Electrochemical Oxidation of NADH at Highly Boron-Doped Diamond ElectrodesAnalytical Chemistry, 1999
- Oxidation of Azide Anion at Boron-Doped Diamond Thin-Film ElectrodesAnalytical Chemistry, 1998
- Peer Reviewed: Boron-Doped Diamond Thin-Film ElectrodesAnalytical Chemistry, 1997