Lung Nodule Detection by Microdose CT Versus Chest Radiography (Standard and Dual-Energy Subtracted)
- 1 April 2015
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 204 (4) , 727-735
Abstract
The purpose of this study was to investigate the feasibility of microdose CT using a comparable dose as for conventional chest radiographs in two planes including dual-energy subtraction for lung nodule assessment. We investigated 65 chest phantoms with 141 lung nodules, using an anthropomorphic chest phantom with artificial lung nodules. Microdose CT parameters were 80 kV and 6 mAs, with pitch of 2.2. Iterative reconstruction algorithms and an integrated circuit detector system (Stellar, Siemens Healthcare) were applied for maximum dose reduction. Maximum intensity projections (MIPs) were reconstructed. Chest radiographs were acquired in two projections with bone suppression. Four blinded radiologists interpreted the images in random order. A soft-tissue CT kernel (I30f) delivered better sensitivities in a pilot study than a hard kernel (I70f), with respective mean (SD) sensitivities of 91.1%±2.2% versus 85.6%±5.6% (p=0.041). Nodule size was measured accurately for all kernels. Mean clustered nodule sensitivity with chest radiography was 45.7%±8.1% (with bone suppression, 46.1%±8%; p=0.94); for microdose CT, nodule sensitivity was 83.6%±9% without MIP (with additional MIP, 92.5%±6%; p<10(-3)). Individual sensitivities of microdose CT for readers 1, 2, 3, and 4 were 84.3%, 90.7%, 68.6%, and 45.0%, respectively. Sensitivities with chest radiography for readers 1, 2, 3, and 4 were 42.9%, 58.6%, 36.4%, and 90.7%, respectively. In the per-phantom analysis, respective sensitivities of microdose CT versus chest radiography were 96.2% and 75% (p<10(-6)). The effective dose for chest radiography including dual-energy subtraction was 0.242 mSv; for microdose CT, the applied dose was 0.1323 mSv. Microdose CT is better than the combination of chest radiography and dual-energy subtraction for the detection of solid nodules between 5 and 12 mm at a lower dose level of 0.13 mSv. Soft-tissue kernels allow better sensitivities. These preliminary results indicate that microdose CT has the potential to replace conventional chest radiography for lung nodule detection.Keywords
This publication has 28 references indexed in Scilit:
- Effective Dose Assessment for Participants in the National Lung Screening Trial Undergoing Posteroanterior Chest Radiographic ExaminationsAmerican Journal of Roentgenology, 2013
- Results of Initial Low-Dose Computed Tomographic Screening for Lung CancerNew England Journal of Medicine, 2013
- Comparison of Dual-Energy Subtraction and Electronic Bone Suppression Combined With Computer-Aided Detection on Chest Radiographs: Effect on Human Observers' Performance in Nodule DetectionAmerican Journal of Roentgenology, 2013
- Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observationsEuropean Radiology, 2012
- Approach to the Ground-Glass NoduleClinics in Chest Medicine, 2011
- Fleischner Society: Glossary of Terms for Thoracic ImagingRadiology, 2008
- Chapters 3 and 4Annals of the ICRP, 2007
- Value of axial and coronal maximum intensity projection (MIP) images in the detection of pulmonary nodules by multislice spiral CT: comparison with axial 1-mm and 5-mm slicesEuropean Radiology, 2005
- Estimation of effective dose to the patient during medical X-ray examinations from measurements of the dose-area productPhysics in Medicine & Biology, 1992
- Measuring nominal scale agreement among many raters.Psychological Bulletin, 1971