Steady-State Analysis of a Canned Line-Start PM Motor
Authors:
- 26 September 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 47 (10) , 4080-4083
Abstract
This paper describes the development of an analytical method for predicting the steady-state response of an integrated “pump-motor-containment.” These pumps employ a canned line-start permanent-magnet motor providing synchronous operation and high load efficiencies. The steady-state performance of the pump motor is assessed under different operating conditions. A laboratory prototype machine is used to validate the model.Keywords
This publication has 11 references indexed in Scilit:
- Determining the equivalent circuit parameters of canned solid-rotor induction motorsIEEE Transactions on Magnetics, 2005
- Modeling and analysis of canned motors for hermetic compressors using combination of 2D and 3D finite element method2003
- Field circuit analysis of permanent magnet synchronous motorsIEEE Transactions on Magnetics, 1994
- Steady-state performance analysis of permanent magnet synchronous motors including space harmonicsIEEE Transactions on Magnetics, 1994
- Analysis of permanent magnet synchronous motorsIEEE Transactions on Industry Applications, 1991
- Performance of large line-start permanent magnet synchronous motorsIEEE Transactions on Energy Conversion, 1990
- Analysis of Cage Induction Motors with Stator Winding FaultsIEEE Transactions on Power Apparatus and Systems, 1985
- Performance of Polyphase Permanent Magnet MachinesIEEE Transactions on Power Apparatus and Systems, 1980
- Field analysis for rotating induction machines and its relationship to the equivalent-circuit methodIEE Proceedings B Electric Power Applications, 1980
- Eddy currents and wall losses in screened-rotor induction motorsProceedings of the IEE - Part A: Power Engineering, 1958