Reliability and day-to-day variability of peak fat oxidation during treadmill ergometry
Open Access
- 5 January 2016
- journal article
- research article
- Published by Taylor & Francis in Journal of the International Society of Sports Nutrition
- Vol. 13 (1) , 4
Abstract
Exercising at intensities where fat oxidation rates are high has been shown to induce metabolic benefits in recreational and health-oriented sportsmen. The exercise intensity (Fatpeak) eliciting peak fat oxidation rates is therefore of particular interest when aiming to prescribe exercise for the purpose of fat oxidation and related metabolic effects. Although running and walking are feasible and popular among the target population, no reliable protocols are available to assess Fatpeak as well as its actual velocity (VPFO) during treadmill ergometry. Our purpose was therefore, to assess the reliability and day-to-day variability of VPFO and Fatpeak during treadmill ergometry running. Sixteen recreational athletes (f = 7, m = 9; 25 ± 3 y; 1.76 ± 0.09 m; 68.3 ± 13.7 kg; 23.1 ± 2.9 kg/m2) performed 2 different running protocols on 3 different days with standardized nutrition the day before testing. At day 1, peak oxygen uptake (VO2peak) and the velocities at the aerobic threshold (VLT) and respiratory exchange ratio (RER) of 1.00 (VRER) were assessed. At days 2 and 3, subjects ran an identical submaximal incremental test (Fat-peak test) composed of a 10 min warm-up (70 % VLT) followed by 5 stages of 6 min with equal increments (stage 1 = VLT, stage 5 = VRER). Breath-by-breath gas exchange data was measured continuously and used to determine fat oxidation rates. A third order polynomial function was used to identify VPFO and subsequently Fatpeak. The reproducibility and variability of variables was verified with an intraclass correlation coefficient (ICC), Pearson’s correlation coefficient, coefficient of variation (CV) and the mean differences (bias) ± 95 % limits of agreement (LoA). ICC, Pearson’s correlation and CV for VPFO and Fatpeak were 0.98, 0.97, 5.0 %; and 0.90, 0.81, 7.0 %, respectively. Bias ± 95 % LoA was −0.3 ± 0.9 km/h for VPFO and −2 ± 8 % of VO2peak for Fatpeak. In summary, relative and absolute reliability indicators for VPFO and Fatpeak were found to be excellent. The observed LoA may now serve as a basis for future training prescriptions, although fat oxidation rates at prolonged exercise bouts at this intensity still need to be investigated.Keywords
This publication has 32 references indexed in Scilit:
- Limited Benefit of Fatmax-Test to Derive Training PrescriptionsInternational Journal of Sports Medicine, 2013
- Relative and absolute reliability of the crossover and maximum fat oxidation points and their relationship to ventilatory thresholdScience & Sports, 2013
- Determination of the exercise intensity that elicits maximal fat oxidation in short-time testingJournal of Sports Sciences, 2013
- Can crossover and maximal fat oxidation rate points be used equally for ergocycling and walking/running on a track?Diabetes & Metabolism, 2012
- Physical Activity Targeted at Maximal Lipid Oxidation: A Meta-AnalysisJournal of Nutrition and Metabolism, 2012
- Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis systemEuropean Journal of Applied Physiology, 2011
- Methodological aspects of crossover and maximum fat-oxidation rate point determinationDiabetes & Metabolism, 2008
- Oxygen Uptake Kinetics During ExerciseSports Medicine, 1999
- Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports MedicineSports Medicine, 1998
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986