Amino acid analysis for peptide quantitation using reversed-phase liquid chromatography combined with multiple reaction monitoring mass spectrometry
Open Access
- 19 July 2023
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (22) , 5261-5267
Abstract
Amino acid analysis (AAA) can be used for absolute quantitation of standard peptides after acid hydrolysis using 6 M HCl. Obtained individual amino acids can then be quantified by liquid chromatography-mass spectrometry (LC–MS). Achieving baseline separation of non-derivatized amino acids is challenging when reversed-phase (RP) chromatography is used. Several derivatization methods are commonly utilized to address this issue; however, derivatization has several drawbacks, such as derivative instability and lack of reproducibility. Currently, separation of non-derivatized amino acids is typically done using HILIC, but HILIC has problems of poor reproducibility and long column equilibration times. We developed a method to quantify non-derivatized amino acids, including methionine and cysteine, from peptide hydrolysates by RP-LC-MS without special pre-treatment of the samples. Samples were spiked with certified isotopically labeled (13C- and/or 15N-) amino acids as internal standards. The amino acids released from acid hydrolysis were then analyzed by RP-UPLC-MRM-MS and quantified using the analyte/internal standard chromatographic peak area ratios. Peptide quantitation was based on the sum of the individual amino acid concentrations from the known peptide sequences. The resulting method did not require derivatization, used standard C18-based reversed-phase liquid chromatography, did not require external calibration, was robust, and was able to quantify all 17 amino acids for which we had internal standards, including the sulfur-containing amino acids, cysteine and methionine, in their respective oxidized forms. This simple and robust method enabled the absolute quantitation of standard peptides using only acid hydrolysis and a standard RP-UPLC-MRM-MS setup. Graphical AbstractKeywords
Funding Information
- Genome Canada (264PRO, 265MET, MC4T)
This publication has 16 references indexed in Scilit:
- Rapid quantification of underivatized amino acids in plasma by hydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass‐spectrometryJournal of Inherited Metabolic Disease, 2016
- Development and validation of an ultra-performance liquid chromatography quadrupole time of flight mass spectrometry method for rapid quantification of free amino acids in human urineAmino Acids, 2015
- Determination of Free Amino Acids in Isatidis Radix By HILIC-UPLC-MS/MSBulletin of the Korean Chemical Society, 2014
- A rapid, sensitive method for quantitative analysis of underivatized amino acids by liquid chromatography–tandem mass spectrometry (LC–MS/MS)Journal of Chromatography B, 2014
- Systematic Comparison of Reverse Phase and Hydrophilic Interaction Liquid Chromatography Platforms for the Analysis of N-Linked GlycansAnalytical Chemistry, 2012
- Amino Acid AnalysisCurrent Protocols in Protein Science, 2009
- The Effect of Hydrolysis Time on Amino Acid AnalysisJournal of AOAC INTERNATIONAL, 2005
- ESI‐MS/MS analysis of underivatised amino acids: a new tool for the diagnosis of inherited disorders of amino acid metabolism. Fragmentation study of 79 molecules of biological interest in positive and negative ionisation modeRapid Communications in Mass Spectrometry, 2003
- Hydrolysis of Samples for Amino Acid Analysis2003
- The contributions of Stein and Moore to protein science.Protein Science, 1993