The Effects of Disinfectants on Dimensional Accuracy and Surface Quality of Impression Materials and Gypsum Casts
Author:
Open Access
- 1 January 2009
- journal article
- Published by Elmer Press, Inc. in Journal of Clinical Medicine Research
- Vol. 1 (2) , 81-9
Abstract
The study aimed to evaluating the effect of disinfecting impression materials on the dimensional accuracy and surface quality of the resulting casts. Impressions of a steel die constructed according to ANSI/ADA specification No.18 were made with each of alginate, addition cured silicone, condensation cured silicone and zinc oxide eugenol paste, and disinfected consequently by each of 0.2% chlorhexidine gluconate, 1% sodium hypochlorite, 2% gluteraldehyde for 5 minutes, and 0.5% sodium hypochlorite for 10 minutes. Dimensions of the disinfected impressions and their resultant casts were measured using a computerized digital caliper, and the dimensional changes were calculated. Reproduction of detail and surface quality of the resultant casts were assessed by grading casts surfaces according to a specific scoring system. The 0.5% sodium hypochlorite was found to produce the least dimensional changes in all the impression materials. Corsodyl produced the maximum changes in both alginate and zinc-oxide eugenol while addition-cured silicon was most affected by Gluteraldehyde and condensation-cured silicon was most affected by Hexana. The dimensional changes, however, were minimal and clinically insignificant. Addition-cured silicon showed the best surface quality and dimensional stability followed by condensation-cured silicon. Alginate and zinc-oxide eugenol had poorer surface quality and were affected to a higher extent by the disinfection procedures. The results were comparable with the standard specifications for dimensional stability. Recommendations were made for the use of 10 minutes immersion in 0.5% sodium hypochlorite as the most appropriate disinfection protocol to the investigated impression materials. Disinfectants; Gypsum casts; Impressions; Alginate; Addition-cured silicone; Sodium hypochlorite.Keywords
This publication has 21 references indexed in Scilit:
- Hygiene in dental practices.2006
- Guidelines for infection control in dental health-care settings--2003.2003
- Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum castsDental Materials, 2002
- The effect of disinfecting alginate and addition cured silicone rubber impression materials on the physical properties of impressions and resultant casts.1998
- INFECTION CONTROL RECOMMENDATIONS FOR THE DENTAL OFFICE AND THE DENTAL LABORATORYThe Journal of the American Dental Association, 1996
- Dimensional stability of dental impressions after immersion disinfectionThe Journal of the American Dental Association, 1986
- Treating highly infectious patients in the dental office.1985
- Preliminary investigation of a method for disinfection of dental impressionsThe Journal of Prosthetic Dentistry, 1984
- Gypsum casts as a potential source of microbial cross-contaminationThe Journal of Prosthetic Dentistry, 1983
- Council adopts American Dental Association Specification No. 18 (Alginate Impression Material)The Journal of the American Dental Association, 1968