Clinical Evaluation of Single-Shot and Readout-Segmented Diffusion-Weighted Imaging in Stroke Patients at 3 T
- 1 April 2013
- journal article
- other
- Published by SAGE Publications in Acta Radiologica
- Vol. 54 (3) , 299-306
Abstract
Background: Diffusion-weighted imaging (DWI) magnetic resonance imaging (MRI) is most commonly performed utilizing a single-shot echo-planar imaging technique (ss-EPI). Susceptibility artifact and image blur are severe when this sequence is utilized at 3 T. Purpose: To evaluate a readout-segmented approach to DWI MR in comparison with single-shot echo planar imaging for brain MRI. Material and Methods: Eleven healthy volunteers and 14 patients with acute and early subacute infarctions underwent DWI MR examinations at 1.5 and 3T with ss-EPI and readout-segmented echo-planar (rs-EPI) DWI at equal nominal spatial resolutions. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) calculations were made, and two blinded readers ranked the scans in terms of high signal intensity bulk susceptibility artifact, spatial distortions, image blur, overall preference, and motion artifact. Results: SNR and CNR were greatest with rs-EPI (8.1±0.2 SNR vs. 6.0±0.2; P -4 at 3T).Spatial distortions were greater with single-shot (0.23±0.03 at 3T; P <0.001) than with rs-EPI (0.12±0.02 at 3T).Combined with blur and artifact reduction, this resulted in a qualitative preference for the readout-segmented scans overall. Conclusion: Substantial image quality improvements are possible with readout-segmented vs. single-shot EPI - the current clinical standard for DWI - regardless of field strength (1.5 or 3 T). This results in improved image quality secondary to greater real spatial resolution and reduced artifacts from susceptibility in MR imaging of the brain.Keywords
This publication has 18 references indexed in Scilit:
- Measuring signal‐to‐noise ratio in partially parallel imaging MRIMedical Physics, 2011
- MR-perfusion (MRP) and diffusion-weighted imaging (DWI) in prostate cancer: Quantitative and model-based gadobenate dimeglumine MRP parameters in detection of prostate cancerEuropean Journal of Radiology, 2010
- ADC measurements of lymph nodes: Inter- and intra-observer reproducibility study and an overview of the literatureEuropean Journal of Radiology, 2010
- Evaluation of a Modified Stejskal-Tanner Diffusion Encoding Scheme, Permitting a Marked Reduction in TE, in Diffusion-Weighted Imaging of Stroke Patients at 3 TInvestigative Radiology, 2010
- Diffusion-Weighted Imaging in Patients With Acute Brain Ischemia at 3 TInvestigative Radiology, 2009
- High resolution diffusion‐weighted imaging using readout‐segmented echo‐planar imaging, parallel imaging and a two‐dimensional navigator‐based reacquisitionMagnetic Resonance in Medicine, 2009
- Reconstruction as a source of artifact in nongated single-shot diffusion-weighted EPIMagnetic Resonance Imaging, 2005
- Practical approaches to the evaluation of signal‐to‐noise ratio performance with parallel imaging: Application with cardiac imaging and a 32‐channel cardiac coilMagnetic Resonance in Medicine, 2005
- Nonlinear phase correction for navigated diffusion imagingMagnetic Resonance in Medicine, 2003
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002