Abstract
Despite many investigations on the corrosion behavior of NiTi shape memory alloys (SMAs) in various simulated physiological solutions by electrochemical measurements, few have reported detailed information on the corrosion products. In the present study, the structure and composition of the corrosion products on NiTi SMAs immersed in a 0.9% NaCl physiological solution are systematically investigated by scanning electron microscopy (SEM), x-ray energy dispersion spectroscopy (EDS), and x-ray photoelectron spectroscopy (XPS). It is found that attack by Cl−results in nickel being released into the solution and decrease in the local nickel concentration at the pitting sites. The remaining Ti reacts with dissolved oxygen from the solution to form titanium oxides. After long-term immersion, the corrosion product layer expands over the entire surface and XPS reveals that the layer is composed of TiO2, Ti2O3, and TiO with relatively depleted Ni. The growth rate of the corrosion product layer decreases with immersion time, and the corrosion product layer is believed to impede further corrosion and improve the biocompatibility of NiTi alloy in a physiological environment. It is found that the release rate of nickel is related to the surface structure of the corrosion product layer and immersion time. A corrosion mechanism is proposed to explain the observed results.Keywords
This publication has 26 references indexed in Scilit:
- Corrosion products on biomedical magnesium alloy soaked in simulated body fluidsJournal of Materials Research, 2009
- Surface structure and properties of biomedical NiTi shape memory alloy after Fenton’s oxidationActa Biomaterialia, 2007
- Characterization of oxide film formed on NiTi by laser oxidationMaterials Science and Engineering: A, 2007
- Effect of pH, temperature and Cl− concentration on electrochemical behavior of NiTi shape memory alloy in artificial salivaJournal of Materials Science: Materials in Medicine, 2006
- In vitro corrosion study by EIS of an equiatomic NiTi alloy and an implant quality AISI 316 stainless steelJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2006
- An overview of nitinol medical applicationsMaterials Science and Engineering: A, 1999
- Nickel release from orthodontic arch wires and cellular immune response to various nickel concentrationsJournal of Biomedical Materials Research, 1999
- Relevant aspects in the clinical applications of NiTi shape memory alloysJournal of Materials Science: Materials in Medicine, 1996
- Surface spectroscopic characterization of TiNi nearly equiatomic shape memory alloys for implantsJournal of Vacuum Science & Technology A, 1995
- Electrochemical corrosion of metallic biomaterialsBiomaterials, 1984