Noninvasive Activity‐based Control of an Implantable Rotary Blood Pump: Comparative Software Simulation Study
Authors:
- 16 February 2010
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 34 (2) , E34-E45
Abstract
A control algorithm for an implantable centrifugal rotary blood pump (RBP) based on a noninvasive indicator of the implant recipient's activity level has been proposed and evaluated in a software simulation environment. An activity level index (ALI)—derived from a noninvasive estimate of heart rate and the output of a triaxial accelerometer—forms the noninvasive indicator of metabolic energy expenditure. Pump speed is then varied linearly according to the ALI within a defined range. This ALI‐based control module operates within a hierarchical multiobjective framework, which imposes several constraints on the operating region, such as minimum flow and minimum speed amplitude thresholds. Three class IV heart failure (HF) cases of varying severity were simulated under rest and exercise conditions, and a comparison with other popular RBP control strategies was performed. Pump flow increases of 2.54, 1.94, and 1.15 L/min were achieved for the three HF cases, from rest to exercise. Compared with constant speed control, this represents a relative flow change of 30.3, 19.8, and −15.4%, respectively. Simulations of the proposed control algorithm exhibited the effective intervention of each constraint, resulting in an improved flow response and the maintenance of a safe operating condition, compared with other control modes.Keywords
This publication has 44 references indexed in Scilit:
- Classification of Physiologically Significant Pumping States in an Implantable Rotary Blood Pump: Patient Trial ResultsASAIO Journal, 2007
- Identification and Classification of Physiologically Significant Pumping States in an Implantable Rotary Blood PumpArtificial Organs, 2006
- Development of a Reliable Automatic Speed Control System for Rotary Blood PumpsThe Journal of Heart and Lung Transplantation, 2005
- Prevalence of self-reported heart failure among US adults: results from the 1999 National Health Interview SurveyAmerican Heart Journal, 2003
- The development of control techniques for ventricular-assist devices and a hierarchical control structure to regulate the operation of a turbo-hydrodynamic assist device - Hierarchical control of heart-assist devicesIEEE Robotics & Automation Magazine, 2003
- Motor Feedback Physiological Control for a Continuous Flow Ventricular Assist DeviceArtificial Organs, 1999
- Detection of Suction and Regurgitation of the Implantable Centrifugal Pump Based on the Motor Current Waveform Analysis and Its Application to Optimization of Pump FlowArtificial Organs, 1999
- Chronotropic incompetence in chronic heart failureInternational Journal of Cardiology, 1995
- Assessment of the heart-rate method for determining energy expenditure in man, using a whole-body calorimeterBritish Journal of Nutrition, 1979