Calibration of an automated California mastitis test with focus on the device-dependent variation
Open Access
- 22 December 2014
- journal article
- research article
- Published by Springer Nature in SpringerPlus
- Vol. 3 (1) , 1-6
Abstract
The aim of the paper was to estimate the accuracy of the metrology of an installed indirect on-line sensor system based on the automated California Mastitis Test (CMT) with focus on the prior established device-dependent variation. A sensor calibration was implemented. Therefore, seven sensors were tested with similar trials on the dairy research farm Karkendamm (Germany) on two days in July 2011 and January 2012. Thereby, 18 mixed milk samples from serial dilutions were fourfold recorded at every sensor. For the validation, independent sensor records with corresponding lab somatic cell score records (LSCS) in the period between both trials were used (n = 1,357). From these records for each sensor a polynomial regression function was calculated. The predicted SCS (PSCS) was obtained for each sensor with the previously determined regression coefficients. Pearson correlation coefficients between PSCS and LSCS were established for each sensor and ranged between r = 0.57 and r = 0.67. Comparing the results with the correlation coefficients between the on-line SCS (OSCS) and the LSCS (r = 0.20 to 0.57) for every sensor, the calibration showed the tendency to improve the installed sensor system.Keywords
This publication has 13 references indexed in Scilit:
- Genetic relationship of conformation traits with average somatic cell score at 150 and 305 days in milk in Holstein cows of IranJournal of Dairy Science, 2012
- Health recording in Canadian Holsteins: Data and genetic parametersJournal of Dairy Science, 2012
- Phenotypic and genetic characterization of novel somatic cell count traits from weekly or monthly observationsJournal of Dairy Science, 2010
- Invited review: Technical solutions for analysis of milk constituents and abnormal milkJournal of Dairy Science, 2010
- Mastitis detection: current trends and future perspectivesTrends in Biotechnology, 2009
- Automatic Detection of Clinical Mastitis Is Improved by In-Line Monitoring of Somatic Cell CountJournal of Dairy Science, 2008
- Use of domestic detergents in the California mastitis test for high somatic cell counts in milkVeterinary Record, 2008
- Rheology of the gel formed in the California Mastitis TestJournal of Dairy Research, 2008
- Reflectance measurement of canopy biomass and nitrogen status in wheat crops using normalized difference vegetation indices and partial least squares regressionRemote Sensing of Environment, 2003
- An Optimum Transformation for Somatic Cell Concentration in MilkJournal of Dairy Science, 1980