A Pilot Study Quantifying Center of Mass Trajectory during Dynamic Balance Tasks Using an HTC Vive Tracker Fixed to the Pelvis
Open Access
Abstract
Fall rates are increasing among the aging population and even higher falls rates have been reported in populations with neurological impairments. The Berg Balance Scale is often used to assess balance in older adults and has been validated for use in people with stroke, traumatic brain injury, and Parkinson’s disease. While the Berg Balance Scale (BBS) has been found to be predictive of the length of rehabilitation stay following stroke, a recent review concluded the BBS lacked predictive validity for fall risk. Conversely, sophisticated measures assessing center of mass (COM) displacement have shown to be predictive of falls risk. However, calculating COM displacement is difficult to measure outside a laboratory. Accordingly, we sought to validate COM displacement measurements derived from an HTC Vive tracker secured to the pelvis by comparing it to COM derived from ‘gold’ standard laboratory-based full-body motion capture. Results showed that RMS between the COM calculated from HTC Vive tracker and full body motion capture agree with an average error rate of 2.1 ± 2.6 cm. Therefore, we conclude measurement of COM displacement using an HTC Vive tracker placed on the pelvis is reasonably representative of laboratory-based measurement of COM displacement.Keywords
This publication has 36 references indexed in Scilit:
- Review of fall risk assessment in geriatric populations using inertial sensorsJournal of NeuroEngineering and Rehabilitation, 2013
- A clinical study to assess fall risk using a single waist accelerometerInformatics for Health and Social Care, 2009
- Correlation of accelerometry with clinical balance tests in older fallers and non-fallersAge and Ageing, 2008
- Usefulness of the Berg Balance Scale in Stroke Rehabilitation: A Systematic ReviewPhysical Therapy, 2008
- Use of the Berg Balance Scale for Predicting Multiple Falls in Community-Dwelling Elderly People: A Prospective StudyPhysical Therapy, 2008
- Assessment of fall-risk by means of a neural network based on parameters assessed by a wearable device during posturographyMedical Engineering & Physics, 2007
- Investigation of fall-risk using a wearable device with accelerometers and rate gyroscopesPhysiological Measurement, 2006
- Development and initial validation of the Falls Efficacy Scale-International (FES-I)Age and Ageing, 2005
- Tremors in Early Parkinsonʼs DiseaseClinical Neuropharmacology, 1989
- Falls and Parkinsonʼs DiseaseClinical Neuropharmacology, 1989