Comparison of Outcomes after Phacoemulsification with Two Different Corneal Incision Distances Anterior to the Limbus
Open Access
- 19 August 2019
- journal article
- research article
- Published by Hindawi Limited in Journal of Ophthalmology
- Vol. 2019, 1-7
Abstract
Purpose. To compare visual performance and visual quality outcomes after phacoemulsification with two different clear corneal incision (CCI) distances anterior to the limbus in senile cataract patients. Methods. Retrospective case series. Patients who had undergone phacoemulsification were divided into two groups according to the CCI distances anterior to the limbus. The CCI distances in group A range from 1 mm to 1.5 mm, while those in group B range from 0.5 mm to 1 mm. The visual acuity, refraction, surgically induced astigmatism (SIA), corneal aberrations, anterior segment parameters, and subjective vision quality were evaluated. Results. This study enrolled 54 eyes, with 27 eyes per group. Both groups had significant improvement in postoperative uncorrected visual acuity (UCVA) and corrected distance visual acuity (CDVA) (). There were no statistically significant between-group differences in postoperative UDVA, CDVA, SIA, corneal aberrations, anterior segment parameters, or VF-QOL questionnaire performance (). Conclusions. The phacoemulsification with CCI distances ranging from 0.5 mm to 1.5 mm is an effective and safe therapy to senile cataract. The CCI distance anterior to the limbus that ranges from 0.5 mm to 1.5 mm is recommended for routine phacoemulsification.
Keywords
Funding Information
- Key Program of Research and Development of Shaanxi, China (2018ZDXM-SF-045, 2017116SF/YX010(10), 2017SF-266)
This publication has 28 references indexed in Scilit:
- Quality of life and visual function in Nigeria: findings from the National Survey of Blindness and Visual ImpairmentBritish Journal of Ophthalmology, 2011
- Quality of life evaluation after implantation of 2 multifocal intraocular lens models and a monofocal modelJournal of Cataract & Refractive Surgery, 2011
- LASIK Outcomes Following Multifocal and Monofocal Intraocular Lens ImplantationJournal of Refractive Surgery, 2010
- Evaluation of anterior segment parameter changes using the Pentacam after uneventful phacoemulsificationActa Ophthalmologica, 2010
- Coaxial, microcoaxial, and biaxial microincision cataract surgeryJournal of Cataract & Refractive Surgery, 2010
- Effect of intraocular lens asphericity on vertical coma aberrationJournal of Cataract & Refractive Surgery, 2010
- Rasch Analysis of Visual Function and Quality of Life QuestionnairesOptometry and Vision Science, 2009
- Calculation of intraocular lens power: a reviewActa Ophthalmologica Scandinavica, 2007
- Wavefront Analysis and Contrast Sensitivity of Aspheric and Spherical Intraocular Lenses: A Randomized Prospective StudyAmerican Journal of Ophthalmology, 2006
- Paired opposite clear corneal incisions to correct preexisting astigmatism in cataract patientsJournal of Cataract & Refractive Surgery, 2005