A Fast, Automated, Polynomial-Based Cosmic Ray Spike–Removal Method for the High-Throughput Processing of Raman Spectra
- 1 April 2013
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 67 (4) , 457-462
Abstract
Raman spectra often contain undesirable, randomly positioned, intense, narrow-bandwidth, positive, unidirectional spectral features generated when cosmic rays strike charge-coupled device cameras. These must be removed prior to analysis, but doing so manually is not feasible for large data sets. We developed a quick, simple, effective, semi-automated procedure to remove cosmic ray spikes from spectral data sets that contain large numbers of relatively homogenous spectra. Although some inhomogeneous spectral data sets can be accommodated—it requires replacing excessively modified spectra with the originals and removing their spikes with a median filter instead—caution is advised when processing such data sets. In addition, the technique is suitable for interpolating missing spectra or replacing aberrant spectra with good spectral estimates. The method is applied to baseline-flattened spectra and relies on fitting a third-order (or higher) polynomial through all the spectra at every wavenumber. Pixel intensities in excess of a threshold of 3 × the noise standard deviation above the fit are reduced to the threshold level. Because only two parameters (with readily specified default values) might require further adjustment, the method is easily implemented for semi-automated processing of large spectral sets.Keywords
This publication has 24 references indexed in Scilit:
- Preprocessing strategies to improve MCR analyses of hyperspectral imagesChemometrics and Intelligent Laboratory Systems, 2012
- An Improved Algorithm to Remove Cosmic Spikes in Raman Spectra for Online MonitoringApplied Spectroscopy, 2011
- Information‐theoretic chemometric analyses of Raman data for chemical reaction studiesJournal of Raman Spectroscopy, 2011
- Automated Raman spectral preprocessing of bone and other musculoskeletal tissues2009
- A Practical Algorithm to Remove Cosmic Spikes in Raman Imaging Data for Pharmaceutical ApplicationsApplied Spectroscopy, 2007
- In Situ Analysis of Living Embryonic Stem Cells by Coherent Anti-Stokes Raman MicroscopyAnalytical Chemistry, 2007
- Investigation of Selected Baseline Removal Techniques as Candidates for Automated ImplementationApplied Spectroscopy, 2005
- Novel Use of a Static Modification of Two-Dimensional Correlation Analysis. Part I: Comparison of the Secondary Structure Sensitivity of Electronic Circular Dichroism, FT-IR, and Raman Spectra of ProteinsApplied Spectroscopy, 1999
- Embryonic Stem Cell Lines Derived from Human BlastocystsScience, 1998
- Simple and Efficient Method to Eliminate Spike Noise from Spectra Recorded on Charge-Coupled Device DetectorsApplied Spectroscopy, 1993