Variability of respiratory parameters and extubation readiness in ventilated neonates
Authors:
- Colin J MorleyCMColin J Morley
- Guilherme M Sant'ANnaGSGuilherme M Sant'ANna
- 3 May 2012
- journal article
- Published by BMJ in Archives of Disease in Childhood - Fetal and Neonatal Edition
- Vol. 98 (1) , F70-F73
Abstract
Background: A spontaneous breathing trial (SBT) has been used to guide suitability of extubation in VLBW infants. Respiratory variability (RV) has been used to assess extubation readiness in adults but was never investigated in preterms. The combination of a SBT and RV may further improve prediction of successful extubation.Study design: Using data previously collected during the SBT, the following respiratory variables were analysed: inspiratory time (TI), expiratory time (TE), TI/total breath time, tidal volume (VT) and mean inspiratory flow (VT/TI). RV was quantified using time-domain analysis for each respiratory variable and expressed as a variability index (VI). The sensitivity, specificity, positive and negative predictive values (PPV and NPV) of the SBT, each VI and combined SBT+VI were calculated. Extubation failure was defined as need of re-intubation within 72 h.Results: A total of 44 infants were included. Successfully (n=36) and unsuccessfully (n=8) extubated infants had similar baseline characteristics and number of breaths analysed. VI for VT/TIwas significantly decreased in the failure group. The combination of the SBT and VI of either TIor VTwere the most accurate predictors of successful extubation with a sensitivity of 100% and specificity of 75% and a PPV and NPV for extubation success of 95% and 100%, respectively.Conclusions: A significant decrease in VT/TIvariability occurred in infants requiring re-intubation. The combination of a SBT failure and decreased variability in TIor VTwas highly predictive of failure. This combination is promising but requires prospective evaluation in a larger population.Keywords
This publication has 38 references indexed in Scilit:
- Mortality Reduction by Heart Rate Characteristic Monitoring in Very Low Birth Weight Neonates: A Randomized TrialThe Journal of Pediatrics, 2011
- Integration of Early Physiological Responses Predicts Later Illness Severity in Preterm InfantsScience Translational Medicine, 2010
- Early CPAP versus Surfactant in Extremely Preterm InfantsThe New England journal of medicine, 2010
- Effect of weight and age on respiratory complexity in premature neonatesJournal of Applied Physiology, 2009
- Delayed Extubation to Nasal Continuous Positive Airway Pressure in the Immature Baboon Model of Bronchopulmonary Dysplasia: Lung Clinical and Pathological FindingsPediatrics, 2006
- Predicting successful extubation of very low birthweight infantsArchives of Disease in Childhood - Fetal and Neonatal Edition, 2006
- Heart Rate Characteristics Monitoring for Neonatal SepsisIEEE Transactions on Biomedical Engineering, 2005
- Variables Associated with the Early Failure of Nasal CPAP in Very Low Birth Weight InfantsThe Journal of Pediatrics, 2005
- Extremely Low Birthweight Neonates with Protracted Ventilation: Mortality and 18-Month Neurodevelopmental OutcomesThe Journal of Pediatrics, 2005
- Spontaneous minute ventilation is a predictor of extubation failure in extremely-low-birth-weight infantsThe Journal of Maternal-Fetal & Neonatal Medicine, 2004