Exposed Dental Implant? Local Autograft A Saviour!
Open Access
- 1 January 2015
- Vol. 7, 85-88
Abstract
Implant exposure due to faulty placement, posses as the most common reason for implant failure. The implant placed too close to buccal or lingual cortex have lead to such failure on numerous occasions. Also, anatomic variations like the thin buccolingual width of alveolar ridge predispose exposure of the implant. 25-year-old female patient had undergone surgical placement of implants in mandibular anterior region 2 months back in the private dental clinic. The clinician noted Grade I mobility in one of the implants placed. The case was referred to the author. Thin overlying gingiva depicted an entire buccal aspect of the implant, which suggested more than 90 % loss of buccal cortex. According to literature and review of similar case reports, the only way suggested was to surgically remove the implant and wait for 12-24 months for the bone to heal for subsequent placement. Rather than the removal of implants as suggested, the author followed a naval approach of reinforcing buccal cortex using an autogenous cortical block from mandibular symphysis. The reinforcement surgery had certainly saved patients time, money and most importantly limits a crucial period of edentulism, which may be enforced on a patient in case the implant was removed.Keywords
This publication has 8 references indexed in Scilit:
- Implant Surgery Complications: Etiology and TreatmentImplant Dentistry, 2008
- A novel drilling procedure and subsequent bone autograft preparation: a technical note.2007
- Healing of dehiscence‐type defects in implants placed together with different barrier membranes: a comparative clinical studyClinical Oral Implants Research, 2004
- Viability of autogenous bone grafts obtained by using bone collectors: histological and microbiological studyPesquisa Odontológica Brasileira, 2003
- Bone collected during dental implant surgery: a clinical and histological studyClinical Oral Implants Research, 2002
- Comparison of four bone collectors designed for oral and maxillofacial surgery ‐ an in vitro studyClinical Oral Implants Research, 1998
- Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part I: Relationship between drill speed and heat production.1998
- Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: Relationship between drill speed and healing.1998