Investigation of Prothrombin Time in Human Whole-Blood Samples with a Quartz Crystal Biosensor
- 14 December 2009
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (2) , 658-663
Abstract
Monitoring of blood coagulation and fibrinolysis is an important issue in treatment of patients with cardiovascular problems and in surgery when blood gets into contact with artificial surfaces. In this work a new method for measuring the coagulation time (prothrombin time, PT) of human whole-blood samples based on a quartz crystal microbalance (QCM) biosensor is presented. The 10 MHz sensors used in this work respond with a frequency shift to changes in viscosity during blood clot formation. For driving and for readout of the quartz, both a network analyzer and an oscillator circuit were utilized. The sensor surfaces were specifically coated with a thin polyethylene layer. We found that both frequency analysis methods are suitable to measure exact prothrombin times in a very good conformity with a mechanical coagulometer as a reference. The anticoagulant effect of heparin on the prothrombin time was exemplarily shown as well as the reverse effect of the heparin antagonist polybrene. The change of the viscoelastic properties during blood coagulation, reflected by the ratio of frequency and dissipation shifts, is discussed for different dilutions of the whole-blood samples. In conclusion, QCM is a distinguished biosensor technique to determine prothrombin time and to monitor heparin therapy in whole-blood samples. Due to the excellent potential of miniaturization and the availability of direct digital signals, the method is predestinated for incorporation and integration into other devices and is thus opening the field of application for inline coagulation diagnostic in extracorporeal blood circuits.Keywords
This publication has 25 references indexed in Scilit:
- Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfacesBiosensors and Bioelectronics, 2005
- Monitoring blood coagulation with magnetoelastic sensorsBiosensors and Bioelectronics, 2003
- Wireless Magnetoelastic Resonance Sensors: A Critical ReviewSensors, 2002
- Comparison of surface plasmon resonance and quartz crystal microbalance in the study of whole blood and plasma coagulationBiosensors and Bioelectronics, 2000
- Surface plasmon resonance (SPR) analysis of coagulation in whole blood with application in prothrombin time assayBiosensors and Bioelectronics, 1999
- Energy Dissipation Kinetics for Protein and Antibody−Antigen Adsorption under Shear Oscillation on a Quartz Crystal MicrobalanceLangmuir, 1998
- Quartz crystal microbalance setup for frequency and Q-factor measurements in gaseous and liquid environmentsReview of Scientific Instruments, 1995
- Automation and prothrombin time: a United Kingdom field study of two widely used coagulometers.Journal of Clinical Pathology, 1990
- Notizen: Radiative Decay of Non Radiative Surface Plasmons Excited by LightZeitschrift für Naturforschung A, 1968