Force-Controlled Biomechanical Simulation of Orthodontic Tooth Movement with Torque Archwires Using HOSEA (Hexapod for Orthodontic Simulation, Evaluation and Analysis)
Open Access
- 7 September 2023
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 10 (9) , 1055
Abstract
This study aimed to investigate the dynamic behavior of different torque archwires for fixed orthodontic treatment using an automated, force-controlled biomechanical simulation system. A novel biomechanical simulation system (HOSEA) was used to simulate dynamic tooth movements and measure torque expression of four different archwire groups: 0.017″ x 0.025″ torque segmented archwires (TSA) with 30° torque bending, 0.018″ x 0.025″ TSA with 45° torque bending, 0.017″ x 0.025″ stainless steel (SS) archwires with 30° torque bending and 0.018″ x 0.025″ SS with 30° torque bending (n = 10/group) used with 0.022″ self-ligating brackets. The Kruskal–Wallis test was used for statistical analysis (p < 0.050). The 0.018″ x 0.025″ SS archwires produced the highest initial rotational torque moment (My) of −9.835 Nmm. The reduction in rotational moment per degree (My/Ry) was significantly lower for TSA compared to SS archwires (p < 0.001). TSA 0.018″ x 0.025″ was the only group in which all archwires induced a min. 10° rotation in the simulation. Collateral forces and moments, especially Fx, Fz and Mx, occurred during torque application. The measured forces and moments were within a suitable range for the application of palatal root torque to incisors for the 0.018″ x 0.025″ archwires. The 0.018″ x 0.025″ TSA reliably achieved at least 10° incisal rotation without reactivation.Keywords
This publication has 38 references indexed in Scilit:
- Measurements of the torque moment in various archwire-bracket-ligation combinationsEuropean Journal of Orthodontics, 2011
- Bracket slot and archwire dimensions: manufacturing precision and third order clearanceJournal of Orthodontics, 2010
- Quantification of three-dimensional orthodontic force systems of T-loop archwiresThe Angle Orthodontist, 2010
- Limitation of Finite Element Analysis of Poroelastic Behavior of Biological Tissues Undergoing Rapid LoadingAnnals of Biomedical Engineering, 2010
- Optimal Loading Conditions for Controlled Movement of Anterior Teeth in Sliding MechanicsThe Angle Orthodontist, 2009
- Three-dimensional orthodontic force measurementsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Location of the centers of resistance for anterior teeth during retraction using the laser reflection techniqueAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1987
- The super-elastic property of the Japanese NiTi alloy wire for use in orthodonticsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1986
- Holographic determination of centers of rotation produced by orthodontic forcesAmerican Journal of Orthodontics, 1980
- Optimizing anterior and canine retractionAmerican Journal of Orthodontics, 1976