Whole‐heart coronary MRA with 100% respiratory gating efficiency: Self‐navigated three‐dimensional retrospective image‐based motion correction (TRIM)
Open Access
- 7 February 2013
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 71 (1) , 67-74
Abstract
Purpose: To develop a three‐dimensional retrospective image‐based motion correction technique for whole‐heart coronary MRA with self‐navigation that eliminates both the need to setup a diaphragm navigator and gate the acquisition.Methods: The proposed technique uses one‐dimensional self‐navigation to track the superior–inferior translation of the heart, with which the acquired three‐dimensional radial k‐space data is segmented into different respiratory bins. Respiratory motion is then estimated in image space using an affine transform model and subsequently this information is used to perform efficient motion correction in k‐space. The performance of the proposed technique on healthy volunteers is compared with the conventional navigator gating approach as well as data binning using diaphragm navigator.Results: The proposed method is able to reduce the imaging time to 7.1±0.5 min from 13.9±2.6 min with conventional navigator gating. The scan setup time is reduced as well due to the elimination of the navigator. The proposed method yields excellent image quality comparable with either conventional navigator gating or the navigator binning approach.Conclusion: We have developed a new respiratory motion correction technique for coronary MRA that enables 1 mm3 isotropic resolution and whole‐heart coverage with 7 min of scan time. Further tests on patient population are needed to determine its clinical usage. Magn Reson Med 71:67–74, 2014.Keywords
This publication has 26 references indexed in Scilit:
- Compressed‐sensing motion compensation (CosMo): A joint prospective–retrospective respiratory navigator for coronary MRIMagnetic Resonance in Medicine, 2011
- Nonrigid retrospective respiratory motion correction in whole‐heart coronary MRAMagnetic Resonance in Medicine, 2011
- 3D radial sampling and 3D affine transform-based respiratory motion correction technique for free-breathing whole-heart coronary MRA with 100% imaging efficiencyMagnetic Resonance in Medicine, 2011
- Assessment of Coronary Artery Disease Using Magnetic Resonance Coronary AngiographyJACC, 2010
- A dual‐projection respiratory self‐gating technique for whole‐heart coronary MRAJournal of Magnetic Resonance Imaging, 2008
- Direct monitoring of coronary artery motion with cardiac fat navigator echoesMagnetic Resonance in Medicine, 2003
- Reduction of transient signal oscillations in true‐FISP using a linear flip angle series magnetization preparationMagnetic Resonance in Medicine, 2002
- Respiratory motion in coronary magnetic resonance angiography: A comparison of different motion modelsJournal of Magnetic Resonance Imaging, 2002
- Calculation of a Subject-Specific Adaptive Motion-Correction Factor for Improved Real-Time Navigator Echo-Gated Magnetic Resonance Coronary AngiographyJournal of Cardiovascular Magnetic Resonance, 1999
- Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary ImagingMagnetic Resonance in Medicine, 1995