Abstract
Background: High-intensity focused ultrasound (HIFU) is a cosmetic procedure that aims to tone the skin through thermal collagen coagulation. The energy is delivered in the deep layers of the skin, and because of these characteristics, the risks of severe damage to adjacent tissue and the ocular surface may be underestimated. Previous reports have demonstrated superficial corneal opacities, cataracts, increased intraocular pressure, or ocular refractive changes in different patients following HIFU. In this case, we report deep stromal opacities associated with anterior uveitis, iris atrophy and lens opacity formation following a single HIFU superior eyelid application. Case presentation: A 47-year-old female presented to the ophthalmic emergency department complaining of pain, hyperemia and photophobia in the right eye following a HIFU application to the superior right eyelid. A slit lamp examination showed three temporal-inferior corneal infiltrates with edema and severe anterior uveitis. The patient was treated with topical corticosteroids, and six months later, there was residual corneal opacity, iris atrophy and peripherical cataract formation. No surgical procedure was needed, and the final vision was Snellen 20/20 (1.0). Conclusion: The risk of severe impairment to the ocular surface and ocular tissues may be underestimated. Cosmetic surgeons and ophthalmologists must be aware of the complications, and the long-term follow-up of these changes needs further investigation and discussion. Safety protocols of the HIFU intensity threshold for thermal lesions in the eye and the use of protective eye devices should be better evaluated.Keywords
This publication has 12 references indexed in Scilit:
- Eye damage due to cosmetic ultrasound treatment: a case reportBMC Ophthalmology, 2018
- Epithelial changes with corneal punctate epitheliopathy in type 2 diabetes mellitus and their correlation with time to healingBMC Ophthalmology, 2018
- Complications from microfocused transcutaneous ultrasound: Case series and review of the literatureLasers in Surgery and Medicine, 2017
- Focused ultrasound in ophthalmologyClinical Ophthalmology, 2016
- The corneal fibrosis response to epithelial–stromal injuryExperimental Eye Research, 2016
- Corneal stromal damage through the eyelid after tightening using intense focused ultrasoundCanadian Journal of Ophthalmology, 2015
- Nonsurgical Rejuvenation of the Upper Eyelid and BrowClinics in Plastic Surgery, 2013
- Thermal Modification of Connective Tissues: Basic Science Considerations and Clinical ImplicationsJournal of the American Academy of Orthopaedic Surgeons, 2000
- Production of Corneal Lesions Using High-Intensity Focused UltrasoundCornea, 1990
- EXPERIMENTAL CATARACT PRODUCTION BY HIGH-FREQUENCY ULTRASOUND1978