Public Street Lighting (PSL) is a critical infrastructure for ensuring the safety and comfort of the community. However, the use of LED-based lighting loads in the PSL network can affect power quality, particularly in terms of total harmonic distortion (THD), voltage drop, and power factor (Cos φ). These conditions require an analytical method capable of evaluating several parameters to obtain a more comprehensive assessment of the PSL network’s power quality. This study analyzes power quality in the PSL network in Semarang City using the Fuzzy method. The parameters THD, voltage drop, cos φ, and distance to the transformer are used as input variables that are processed through the stages of fuzzification, rule-based inference, and defuzzification to generate a power quality. This approach is used to integrate various electrical parameter conditions into a single value and power quality category. The research results show that the Fuzzy Logic is capable of classifying power quality based on a combination of input parameters. The result concludes that Fuzzy Logic is an effective and efficient approach for improving power quality in street lighting networks. Various promising avenues for future development include integrating this methodology with real-time power quality monitoring and developing more adaptive fuzzy algorithms to address dynamic fluctuations in electrical systems. In several test scenarios, PQ values of 0.22 (categorized as “Bad”), 0.50 (categorized as “Very Bad”), and 0.78 (categorized as “Good”) were obtained. These results indicate that the Fuzzy Logic method can be used as a flexible approach to evaluate the power quality of street lighting networks based on varying electrical conditions.