The impact of cataract severity on measurement acquisition with the IOLMaster
Authors:
Open Access
- 24 May 2005
- journal article
- Published by Wiley in Acta Ophthalmologica Scandinavica
- Vol. 83 (4) , 439-442
Abstract
: Purpose: The Zeiss IOLMaster optical biometry system provides superior prediction of refractive outcome of cataract surgery compared to applanation ultrasound. However, measurement is not always possible in the presence of dense cataract. The purpose of this study was to elucidate the rate of measurement acquisition failure due to cataract and how this varies with morphology and severity. Methods: A total of 149 subjects were prospectively enrolled and visual acuity, Lens Opacities Classification System III (LOCS III) scores, ultrasonic A‐scan and IOLMaster axial lengths were measured. Chi‐squared analysis was used to test the null hypothesis that cataract severity has no effect on measurement failure rate. Results: Measurements could not be obtained with the IOLMaster in nine cases for reasons other than cataract. Cataract caused measurement acquisition failure in 22 (15.9%) cases, including all mature cataracts (n = 3) and posterior subcapsular cataracts (PSC) with LOCS III (p > 3.5; n = 18). The null hypothesis was accepted for cortical (χ2 = 2.94, d.f. = 2, p > 0.05) and nuclear (χ2 = 7.91, d.f. = 4, p > 0.05) cataract, but rejected for PSC (χ2 = 111, d.f. = 3, p < 0.001). All cases could be measured with ultrasound. Conclusions: The IOLMaster fails to acquire axial length measurement in approximately 20% of UK public hospital cataract patients. Failure is principally due to PSC, whereby the LOCS III score of p = 3.5 defines the limit of PSC severity that the IOLMaster can measure.Keywords
This publication has 17 references indexed in Scilit:
- Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyesJournal of Cataract & Refractive Surgery, 2003
- Comparison of biometric measurements using partial coherence interferometry and applanation ultrasoundJournal of Cataract & Refractive Surgery, 2003
- Clinical assessment of the Zeiss IOLMasterJournal of Cataract & Refractive Surgery, 2003
- Partial coherence laser interferometry vs conventional ultrasound biometry in intraocular lens power calculationsEye, 2002
- Immersion A-scan compared with partial coherence interferometryJournal of Cataract & Refractive Surgery, 2002
- Refractive outcome of cataract surgery using partial coherence interferometry and ultrasound biometryJournal of Cataract & Refractive Surgery, 2002
- Biometry of cataractous eyes using partial coherence interferometryJournal of Cataract & Refractive Surgery, 2002
- Standardizing the Measurement of Visual Acuity for Clinical Research StudiesOphthalmology, 1996
- The Lens Opacities Classification System IIIArchives of Ophthalmology (1950), 1993
- A Comparison Of Ultrasonographic And Optical Methods For Determining The Axial Length Of The Aphakic EyeAmerican Journal of Ophthalmology, 1966