Transmission of Interior Concrete Column Loads through Floors
Authors:
- 1 June 1998
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 124 (6) , 602-610
Abstract
Clause 10.15.3 of the 1995 ACI code (ACI 318-95) defines the effective strength of a high-strength concrete interior column with an intervening normal strength concrete slab. This provision is based on laboratory tests in which no load was applied to the slab. Such tests may overestimate the strength of the column because they do not properly model the confinement conditions of the column-slab joint. This paper reports experimental results of tests with properly modeled confinement conditions. The test results show that the intensity of slab load, the aspect ratio of the joint, and the rectangularity of the column affect the strength of an interior column-slab joint. A new design equation replacing the provision in Clause 10.15.3 is proposed.Keywords
This publication has 1 reference indexed in Scilit:
- Tests of High‐Strength Concrete Columns with Intervening Floor SlabsJournal of Structural Engineering, 1991