Abstract
A liquid refractive index sensor is designed and optimized by using silicon-rods based on a 10-fold photonic quasicrystal without defects. The resonant mode with high Q value is chosen as the sensing wavelength in the transmission spectrum. By changing the radius of the silicon pillars, the sensor size and the refractive index of the background media, different types of sensors are designed and investigated. On the other hand, the performance of the sensor is investigated including the measurement range, sensitivity, etc. In the detection limit of spectral instruments, 0.02 nm, the sensing accuracy is 10 −4 refractive index unit with a figure of merit of 1478. The measurement range is from 1.2731 to 1.4185. This will provide a new method for the design and fabrication of lab-on-chip, microfluidic optical elements and integrated optical circuits.
Funding Information
  • Opening Foundation of the Key Laboratory of Semiconductor Materials Science Institute of Semiconductors of Chinese Academy of Sciences (KLSMS-1608)
  • China Scholarship Council (201607040011)
  • Science and Technology Major Project of Henan province (161100210200)
  • Opening Foundation of State Key Laboratory of Fire Science (HZ2016-KF01)
  • Foundation Research Project of Henan Province (152300410023)

This publication has 17 references indexed in Scilit: