Comparison of 2D radiography and a semi-automatic CT-based 3D method for measuring change in dorsal angulation over time in distal radius fractures
- 27 February 2016
- journal article
- research article
- Published by Springer Nature in Skeletal Radiology
- Vol. 45 (6) , 763-769
Abstract
The aim of the present study was to compare the reliability and agreement between a computer tomography-based method (CT) and digitalised 2D radiographs (XR) when measuring change in dorsal angulation over time in distal radius fractures. Radiographs from 33 distal radius fractures treated with external fixation were retrospectively analysed. All fractures had been examined using both XR and CT at six times over 6 months postoperatively. The changes in dorsal angulation between the first reference images and the following examinations in every patient were calculated from 133 follow-up measurements by two assessors and repeated at two different time points. The measurements were analysed using Bland-Altman plots, comparing intra- and inter-observer agreement within and between XR and CT. The mean differences in intra- and inter-observer measurements for XR, CT, and between XR and CT were close to zero, implying equal validity. The average intra- and inter-observer limits of agreement for XR, CT, and between XR and CT were ± 4.4°, ± 1.9° and ± 6.8° respectively. For scientific purpose, the reliability of XR seems unacceptably low when measuring changes in dorsal angulation in distal radius fractures, whereas the reliability for the semi-automatic CT-based method was higher and is therefore preferable when a more precise method is requested.Keywords
This publication has 25 references indexed in Scilit:
- Comparison of three dimensional and radiographic measurements in the analysis of distal radius malunionJournal of Hand Surgery (European Volume), 2012
- The Total Deviation Index estimated by Tolerance Intervals to evaluate the concordance of measurement devicesBMC Medical Research Methodology, 2010
- Rapid and effective segmentation of 3D models using random walksComputer Aided Geometric Design, 2009
- The Reliability of Measurements Taken from Computer-Stored Digitalised X-Rays of Acute Distal Radius FracturesJournal of Hand Surgery (European Volume), 2008
- Image-based RSA: Roentgen stereophotogrammetric analysis based on 2D–3D image registrationJournal of Biomechanics, 2008
- Essential Radiographic Evaluation for Distal Radius FracturesHand Clinics, 2005
- A method for registration of 3-D shapesIEEE Transactions on Pattern Analysis and Machine Intelligence, 1992
- Marching cubes: A high resolution 3D surface construction algorithmACM SIGGRAPH Computer Graphics, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Random sample consensusCommunications of the ACM, 1981