Ultrasound biomicroscopy of silicone posterior chamber phakic intraocular lens for myopia
Authors:
- Julián García-FeijoóJGJulián García-Feijoó
- José L. Hernández-MatamorosJHJosé L. Hernández-Matamoros
- Carmen Méndez-HernándezCMCarmen Méndez-Hernández
- Alfredo Castillo-GómezACAlfredo Castillo-Gómez
- Carlos LázaroCLCarlos Lázaro
- Teresa MartínTMTeresa Martín
- Ricardo Cuiña-SardiñaRCRicardo Cuiña-Sardiña
- Julián García-SánchezJGJulián García-Sánchez
- 1 October 2003
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 29 (10) , 1932-1939
Abstract
To study the intraocular position and anatomic relationships of PRL-III (phakic refractive lens) (PRL) posterior chamber phakic intraocular lens (PCP IOL) for high myopia using ultrasound biomicroscopy (UBM). Centro Oftalmológico Real Vision, and Instituto de Investigaciones Oftalmológicas Ramón Castroviejo, Universidad Complutense de Madrid, Madrid, Spain. Sixteen phakic myopic eyes that had had PRL implantation were examined by UBM 1 month after surgery. The PRL position, PRL-crystalline lens peripheral distance, and central distance between the corneal endothelium and the PRL were measured. Both haptics were on the zonule in 6 eyes, in the ciliary sulcus in 5 eyes, and impacted in the ciliary body in 1 eye. In the 4 remaining eyes, the haptics were in mixed positions. The mean PCP IOL crystalline lens peripheral distance in the minor axis was 588.1 microm +/- 232.5 (SD), and the mean PCP IOL-endothelium central distance was 2082.8 +/- 277.6 microm. Phakic refractive lens implantation should be done carefully because of the sulcus location of the haptics in many cases. This, with the iris-PRL contact, suggests caution for the long-term outcome.Keywords
This publication has 32 references indexed in Scilit:
- Implantable contact lens for moderate to high myopiaJournal of Cataract & Refractive Surgery, 2001
- Phakic anterior chamber lenses for the correction of myopiaOphthalmology, 1999
- Cataract development after implantationof the Staar Collamer posterior chamber phakic lensJournal of Cataract & Refractive Surgery, 1999
- Cataract formation after posterior chamber phakic intraocular lens implantationJournal of Cataract & Refractive Surgery, 1998
- Staar Collamer intraocular lens: Clinical results from the Phase I FDA core studyJournal of Cataract & Refractive Surgery, 1998
- Endothelial study of iris-claw phakic lens: Four year follow-upJournal of Cataract & Refractive Surgery, 1998
- Staar Collamer posterior chamber phakic intraocular lens to correct myopia and hyperopiaJournal of Cataract & Refractive Surgery, 1998
- Implantable contact lens for moderate to high myopia: Phase 1 FDA clinical study with 6 month follow-upJournal of Cataract & Refractive Surgery, 1998
- Collamer intraocular contact lens to correct high myopiaJournal of Cataract & Refractive Surgery, 1996
- Posterior chamber myopia lenses in phakic eyesJournal of Cataract & Refractive Surgery, 1996