Computerized ultrasonographic tissue characterization of equine superficial digital flexor tendons by means of stability quantification of echo patterns in contiguous transverse ultrasonographic images
Authors:
- Erwin M. BakkerEBErwin M. Bakker
- A. Mieke JonkerAJA. Mieke Jonker
- P. Rene van WeerenPWP. Rene van Weeren
- 1 March 2003
- journal article
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 64 (3) , 366-375
Abstract
Objective —To describe a method of computerized ultrasonographic tissue characterization that includes structures below the size limits of resolution in equine superficial digital flexor tendons. Sample Population —2 damaged and 2 structurally normal superficial digital flexor tendons. Procedure —Transverse ultrasonographic images were collected along the tendon long axis. Stability of echo pattern was quantified by means of variation in gray levels of each pixel in contiguous images and expressed as correlation, entropy, and waviness ratios. Results —Normal young and normal old tissues were characterized by high correlation and low entropy and waviness ratios. In necrotic tissue, collapsed intratendinous septa resulted in high correlation, moderate entropy, and high waviness ratios. In early granulation tissue, complete lack of bundle formation resulted in values of zero for correlation and waviness ratios; loose connective tissue matrix resulted in a high entropy ratio. In late granulation tissue, formation of new bundles resulted in a high correlation ratio; swollen intratendinous septa and incomplete organization of connective tissue matrix were reflected in high entropy and waviness ratios. In early fibrotic tissue, rearrangement of tendon bundles resulted in a correlation ratio within reference range and a slight increase in the waviness ratio; an increase in cellularity and lack of fibrillar arrangement led to an increase in the entropy ratio. In late fibrotic and scar tissues, inferior quality of repair with almost complete lack of organization was reflected in low to moderate correlation, low waviness, and high entropy ratios. Conclusions and Clinical Relevance —Stability of echo patterns accurately reflects homogeneity of tendons in horses. ( Am J Vet Res 2003;64:366–375)Keywords
This publication has 31 references indexed in Scilit:
- Macroscopic ‘degeneration’ of equine superficial digital flexor tendon is accompanied by a change in extracellular matrix compositionEquine Veterinary Journal, 1998
- Low-Field Magnetic Resonance Imaging (0.2 T) of Tendons With Sonographic and Histologic CorrelationInvestigative Radiology, 1998
- Mechanical properties of pathological equine superficial digital flexor tendonsEquine Veterinary Journal, 1997
- Factors affecting the clinical outcome of injuries to the superficial digital flexor tendon in National Hunt and point-to-point racehorsesVeterinary Record, 1993
- The pathophysiology of flexor tendon injury in the horseEquine Veterinary Education, 1993
- Staging of Patellar Tendon Autograft Healing After Posterior Cruciate Ligament ReconstructionClinical Orthopaedics and Related Research, 1993
- MAGNETIC RESONANCE, ULTRASOUND AND HISTOPATHOLOGIC CORRELATION OF ACUTE AND HEALING EQUINE TENDON INJURIESVeterinary Radiology & Ultrasound, 1992
- A Comparison of Repair Methods for Gap Healing in Equine Flexor TendonVeterinary Surgery, 1990
- Collagen synthesis during primate flexor tendon repair in vitroJournal of Orthopaedic Research, 1990
- Epidemiological study of wastage among racehorses 1982 and 1983Veterinary Record, 1985