Linking computer-aided design (CAD) to Geant4-based Monte Carlo simulations for precise implementation of complex treatment head geometries
Authors:
- Dragos E ConstantinDCDragos E Constantin
- Paul J KeallPKPaul J Keall
- Anisha NarulaANAnisha Narula
- Michelle SvatosMSMichelle Svatos
- Joseph PerlJPJoseph Perl
- 26 March 2010
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (8) , N211-N220
Abstract
Most of the treatment head components of medical linear accelerators used in radiation therapy have complex geometrical shapes. They are typically designed using computer-aided design (CAD) applications. In Monte Carlo simulations of radiotherapy beam transport through the treatment head components, the relevant beam-generating and beam-modifying devices are inserted in the simulation toolkit using geometrical approximations of these components. Depending on their complexity, such approximations may introduce errors that can be propagated throughout the simulation. This drawback can be minimized by exporting a more precise geometry of the linac components from CAD and importing it into the Monte Carlo simulation environment. We present a technique that links three-dimensional CAD drawings of the treatment head components to Geant4 Monte Carlo simulations of dose deposition.Keywords
This publication has 21 references indexed in Scilit:
- Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo‐based photon and electron external beam treatment planningMedical Physics, 2007
- Monte Carlo validation of EYEPLAN proton therapy treatment planningNuclear Physics B - Proceedings Supplements, 2007
- On the discrepancies between Monte Carlo dose calculations and measurements for the Varian photon beamMedical Physics, 2007
- Geant4 developments and applicationsIEEE Transactions on Nuclear Science, 2006
- Validation of Geant4 Physics Models for the Simulation of the Proton Bragg Peak2006
- Verification of the dose distributions with GEANT4 simulation for proton therapy2005
- Validation of Monte Carlo calculated surface doses for megavoltage photon beamsMedical Physics, 2005
- Validation ofGEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physicsMedical Physics, 2004
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Monte Carlo techniques in medical radiation physicsPhysics in Medicine & Biology, 1991